🎯 Find the right ventilation product
Ask our HVAC AI — get specs & recommendation in seconds

Single Way Inline Box Fan

Single Way Inline Box Fan for single-route inline duct ventilation with compact box design

PROJECT FIT
Single Way Inline Box Fan for single-route inline duct ventilation with compact box design
PERFORMANCE RANGE
Single model · inline box fan · single-route design · compact ventilation

Source-backed Silent In-Line Series parameters: partial model coverage

Published source: KCVENTS Silent In-Line Series technical table. Exact source coverage is limited to the ten models listed below. Target models DPT15-40, DPT20-150, DPT20-70, DPT25-210, DPT25-260 and DPT25-320 are not covered by this source and remain pending verification.

Model Voltage (V/Hz) Speed Power (W) Airflow (m³/h) Static Pressure (Pa) Noise (dB) Duct Diameter Φ (mm)
DPT10-12B 220-50 / 23 100 80 20 100
DPT10-24B 220-50 H/L 30/23 200/150 125/100 23 100
DPT15-32B 220-50 H/L 42/33 360/250 160/120 27 150
DPT15-42B 220-50 H/L 103/88 500/400 190/165 29 150
DPT20-54B 220-50 H/L 114/101 770/600 200/195 35 200
DPT20-54C 220-50 H/L 174/146 920/800 240/220 37 200
DPT20-65B 220-50 H/L 253/210 1200/1000 360/320 41 200
DPT25-76B 220-50 H/L 535/480 1700/1500 420/410 43 250
DPT25-76C 220-50 H/L 565/500 1900/1800 430/425 46 250
DPT25-86B 220-50 H/L 800/728 2600/2400 530/510 46 250
Inline duct fan selection

Inline Box Fan Selection Snapshot

Confirm whether a single-way inline box fan fits the duct route and service space before final model approval. Final quotation depends on duct size, installation space, airflow target, static pressure, duct length, bends, voltage, frequency and quantity.

Photo note: use the product image for shape recognition, then confirm duct size, service space and the exact model row before engineering approval.
Project fitsingle-way inline box fan
Applicationboxed inline duct ventilation with serviceable installation space
Project detailsConfirm duct size, installation space, airflow target, static pressure, duct length, bends and voltage/frequency
Source note

HF Series coverage is 100% with high-confidence parameter rows in the PIM/source database. Do not copy values across unrelated duct fan pages.

Specification policy

Use the exact HF model row for selection

Single Way Inline Box Fan technical and selection table
Spec item How to use it Buyer check
Airflow Use the exact HF variant source row Match room volume and ventilation objective.
Static pressure Check against duct length, bends and outlet resistance Do not choose by airflow alone.
Noise Use documented checks dBA value and installation context Confirm if the fan is near occupied areas.
Voltage/frequency Confirm before order Match local project power supply.
Application fit

Where this inline duct fan fits

Single Way Inline Box Fan is suited for boxed inline duct ventilation with serviceable installation space where the buyer needs compact inline installation and a defined duct route.

For long duct runs, multiple bends, filter resistance or strict noise targets, confirm static pressure instead of selecting by nominal airflow only.

Send these details

  • Duct diameter and duct length
  • Number of bends and outlet type
  • Airflow target and noise limit
  • Voltage/frequency and quantity

Core Engineering Features

Source-backed Silent In-Line Series parameters: partial model coverage set against the published values on this page. Every point below is taken from this model’s own data.

Project fitsingle-way inline box fan
Applicationboxed inline duct ventilation with serviceable installation space
Project detailsConfirm duct size, installation space, airflow target, static pressure, duct length, bends and voltage/frequency
Voltage (V/Hz)220-50
Speed/
Power (W)23

Quality Assurance & Warranty

Fan orders are checked at the factory before shipping, because published airflow and pressure only hold if the delivered unit matches its table row.

Applied to this model: Project fit single-way inline box fan, Application boxed inline duct ventilation with serviceable installation space. These checks are run against that specification before the unit ships.

Airflow and pressure checkChecks cover motor start-up, impeller balance, airflow and static pressure verification, noise review and model-to-table parameter matching.
Documented complianceCE, RoHS and related files cover the listed fan families; see the documents section below.
Warranty supportWarranty for fan orders is confirmed with the quotation for your destination market.
Service parts for fansImpellers, motor capacitors, mounting brackets and common service items.

OEM/ODM & Supply Options

For distributors and contractors working on ventilation projects, the supply side adapts to your market instead of one fixed fan build.

For this model (Project fit single-way inline box fan, Application boxed inline duct ventilation with serviceable installation space), the OEM route can start from that base specification rather than a blank sheet.

OEM/ODMBadging, packaging and control options for fan orders, including branded cartons and manual inserts.
Airflow and pressure variantsModel selection, motor power and voltage options are reviewed against your duct calculation.
Voltage & plug optionsVoltage and plug configuration for this product line can be reviewed during quotation.
Documentation & bulk supplyCatalogues, technical sheets, available certificates, volume pricing and distributor programs for this product line.
Order quantity & lead timeMinimum order quantity, sampling and production lead time are confirmed per model and order volume — see the B2B supply page for how sourcing enquiries are handled.

Documents & Compliance

Download the In-Line Series datasheet used for the technical values on this page, and review the relevant compliance documents.

Confirm the exact model, destination-market requirements and current documentation before quotation or project documentation.

Frequently asked questions

Can I choose by duct diameter only?

No. Duct diameter is only the starting point. Confirm airflow, static pressure, duct length and bends.

Why confirm static pressure?

Long ducts, filters and bends reduce actual airflow. Static pressure helps avoid under-selection.

What information is needed for quote?

Send duct diameter, route, airflow target, duct length, bends, outlet type, voltage/frequency, quantity and destination.

Product inquiry

Confirm the published specifications, then add this product to your quote list.

model

, , , , , , , , , , , , , , ,