Model Switch type Dimensions (mm) Voltage (V) Frequency (Hz) Power (W) Speed (m/s) Airflow (m³/h) Noise (dB) Weight (kg)
FM-125-08DT Key Switch 800 × 146 × 173 220 50 80 7.5 860 ≤49 5
FM-125-08DT Inductive Switch 800 × 146 × 173 220 50 80 7.5 860 ≤49 5
FW-125-08DT Stainless Steel Sensor Switch 800 × 146 × 173 220 50 80 7.5 860 ≤49 5

Selection Snapshot

Elevator Air Curtain is organized here as a buyer-facing industrial HVAC product page. This page keeps the product data and adds selection checkpoints, navigation and a quote path.

Performance & Specification Policy

Elevator Air Curtain technical and selection table
Item Selection factors Why it matters
Exact model Confirm by model nameplate or datasheet Avoids mixing similar series or legacy SKUs
Airflow / capacity Confirm required duty point for quote review Keeps selection tied to the project condition
Installation Confirm mounting method, voltage/frequency and site restrictions Reduces mismatch during procurement

Typical Applications

Project fit

Doorway air-separation duty.

Spec reference

Numeric parameters should be finalized only from confirmed source records or the latest datasheet.

Selection guide

  1. Share the target application and installation location.
  2. Confirm exact model, voltage/frequency and duty requirement.
  3. Check whether any certificates, drawings or special materials are required.
  4. Request a source-backed quotation and document review.

Compare the options

Compare this product by exact model, duty point, installation method, site environment, support documents and after-sales requirements, not by title alone.

Can Linggongshare recommend a model directly?

Yes. Send the application, airflow or capacity target, installation constraints and power supply. The team can help narrow the model range.

Are all technical values final on this page?

For safety, final selection should be confirmed against the latest exact-model datasheet or source-backed parameter record.

Elevator Air Curtain selection notes for buyers

Best use case: elevator entrance air separation for dust, odor and comfort control. This page is optimized from existing Linggongshare product content and source-backed database coverage; models without exact source rows are intentionally not used for parameter claims.

Before asking for a quote

  • Confirm the exact installation scene and expected operating duty.
  • Share opening width, mounting space, traffic frequency and preferred control method.
  • Ask Linggong to confirm the final model against available product data for procurement planning.

Core Engineering Features

Source-backed elevator air curtain parameters set against the published values on this page. Every point below is taken from this model’s own data.

Project fitDoorway air-separation duty.
Spec referenceNumeric parameters should be finalized only from confirmed source records or the latest datasheet.
Switch typeKey Switch
Dimensions (mm)800 × 146 × 173
Voltage (V)220
Frequency (Hz)50

Quality Assurance & Warranty

Air curtain orders are checked at the factory before shipping, because barrier performance depends on discharge speed matching the door the unit serves.

Applied to this model: Project fit Doorway air-separation duty., Spec reference Numeric parameters should be finalized only from confirmed source records or the latest datasheet.. These checks are run against that specification before the unit ships.

Discharge and length checkChecks cover motor start-up, discharge air speed, airflow, unit length and panel fit, plus model-to-table parameter matching.
Documented complianceCE and related files cover the listed air curtain families; see the documents section below.
Warranty supportWarranty for air curtain orders is confirmed with the quotation for your destination market.
Service parts for air curtainsMotors, PTC heating modules, control boards and common service items.

OEM/ODM & Supply Options

For distributors and contractors working on entrance projects, the supply side adapts to your market instead of one fixed air curtain build.

For this model (Project fit Doorway air-separation duty., Spec reference Numeric parameters should be finalized only from confirmed source records or the latest datasheet.), the OEM route can start from that base specification rather than a blank sheet.

OEM/ODMBadging, packaging and control options for air curtain orders, including branded cartons and manual inserts.
Length and speed variantsUnit length, discharge speed and ambient or heated configuration are reviewed for your doorway.
Voltage & plug optionsVoltage and plug configuration for this product line can be reviewed during quotation.
Documentation & bulk supplyCatalogues, technical sheets, available certificates, volume pricing and distributor programs for this product line.
Order quantity & lead timeMinimum order quantity, sampling and production lead time are confirmed per model and order volume — see the B2B supply page for how sourcing enquiries are handled.

Documents & Compliance

Download the elevator air curtain datasheet (PDF) used for the technical values on this page.

Confirm the exact model and current documentation before quotation or project documentation.

Frequently Asked Questions

How should I select Elevator Air Curtain?

Start from the installation scene, required duty and exact model confirmation. For Elevator Air Curtain, confirm opening width, mounting space, traffic frequency and preferred control method for product selection.

Can Linggong recommend an exact model for this air curtain project?

Yes. Share the application, installation dimensions and operating conditions so the Linggong team can match a source-backed model instead of guessing from a similar product.

What information should be checked for final selection?

Check power supply, installation space, working environment and maintenance access. If a model is not confirmed in the current database, Linggong will mark it for confirmation rather than invent parameters.

Product inquiry

Confirm the published specifications, then add this product to your quote list.

model

,