HT-DG480A1 Industrial Dehumidifier | 480 L/D Moisture Control
HT-DG480A1 — industrial dehumidifier rated at 480 L/D , 8500 W, 4200 CFM, AC380V/50Hz. Designed for warehouses, production rooms, storage and equipment spaces. Backed by CE LVD/EMC attestation (M.2025.206.C118876) and RoHS technical file. S…
- PRODUCT
- HT-DG480A1 Industrial Dehumidifier | 480 L/D Moisture Control
- CHECK FIRST
- Confirm the exact model and project requirements.
- INQUIRY
- Send your application details for configuration review.
HT-DG480A1 Industrial Dehumidifier | 480 L/D Large-Space Moisture Control
HT-DG480A1 is an industrial dehumidifier option for warehouses, production rooms, storage areas and equipment spaces where moisture control affects comfort, corrosion risk, product storage or process stability.
Selection flow
Project flow
Application fit
Where this model fits, and what to verify first
Technical Parameters
| Model | Dehumidification | Voltage | Input power | Airflow | Size |
|---|---|---|---|---|---|
| HT-DG480A1 | 480 | AC380V/50Hz | 8500 | 4200 | 1200x410x1600 |
Project confirmation: Confirm the exact model, electrical supply, operating environment, installation space and required documents before final order approval.
Best-fit Applications
This is the largest unit in the series, built for spaces where a smaller model cannot keep up: a very large warehouse, a big production hall, or a facility with a consistently heavy moisture load. The 4,200 m³/h airflow is what lets dry air reach across a space of that scale.
It draws 8,500 W on three-phase 380 V, so the electrical supply is a major planning item. Drainage has to handle a high daily condensate volume continuously, and the installation needs clearance around a large floor-standing cabinet.
- Very large warehouses: holds humidity down across a big storage volume all day.
- Big production halls: keeps conditions stable where the load is heaviest.
- High-demand facilities: where any smaller unit would fall short of target RH.
Selection guide
- Moisture load: confirm litres per day against 480 L/D with margin.
- Supply: three-phase 380 V, circuit planned for 8,500 W.
- Air path: match the 4,200 m³/h circulation to a very large space.
- Drain route: continuous drainage sized for a high condensate flow.
- Placement: allow clearance and service access around a large cabinet.
What NOT to Buy
| Situation | Risk | Better action |
|---|---|---|
| Small or medium room | The largest model is oversized and wasteful there. | Step down to a mid-range unit. |
| Insufficient supply | 8,500 W needs a substantial three-phase circuit. | Confirm the electrical supply first. |
| Uncalculated load | Guessing at this capacity is costly. | Work out litres per day. |
| Weak drainage | A high-capacity unit produces a lot of condensate. | Plan a heavy-duty continuous drain. |
Industrial Dehumidifier Buyer Checklist
Use the source-backed product information on this page as the starting point, then confirm site conditions before approving the final model.
- Daily moisture load against 480 L/D
- Three-phase 380 V circuit for 8,500 W
- Air distribution for 4,200 m³/h across a large volume
- Heavy-duty continuous drain and service clearance
HT-DG480A1 is positioned for high-capacity industrial moisture removal; confirm capacity, drainage and site humidity load before final selection.
Core Engineering Features
HT-DG480A1 Industrial Dehumidifier | 480 L/D Large-Space Moisture Cont set against the published values on this page. Every point below is taken from this model’s own data.
Quality Assurance & Warranty
Dehumidifier orders are verified at the factory before shipping, because a unit sized for a humidity target is only useful if it arrives working to that target.
Applied to this model: Capacity 480 L/D, Power AC380V/50Hz. These checks are run against that specification before the unit ships.
OEM/ODM & Supply Options
For distributors and contractors working on moisture-control projects, the supply side adapts to your market instead of one fixed cabinet build.
For this model (Capacity 480 L/D, Power AC380V/50Hz), the OEM route can start from that base specification rather than a blank sheet.
Documents & Compliance
This dehumidifier series is supported by Linggong Electric CE LVD/EMC and RoHS documentation for the listed HT, LG, HT-DG, LG-DG and LG-D dehumidifier model ranges.
- CE AttestationM.2025.206.C118876
- Technical FilesDTCF0509-LVD/EMC and DTCF0509-ROHS
- ApplicantZhejiang Linggong Electric Appliance Co., Ltd.
Scope boundary: use these documents for the dehumidifier model families listed in the certificates. The DTS1250 SGS performance report is not used here because its applicant/model scope does not match Linggongshare pages.
FAQ
How do I choose dehumidifier capacity?
Confirm the daily load against 480 L/D. This is the largest model, so it fits a very large space with a heavy load, and it needs three-phase power, 4,200 m³/h of air path and a heavy-duty drain.
Can it run continuously?
Yes. At 8,500 W on three-phase 380 V with 4,200 m³/h, it is built for continuous duty, provided the circuit and drain are sized for it. Keep the filter, air path and high-volume drain all clear, and allow service access around a large cabinet. At this capacity the drain and the electrical circuit are the two items that must be right.
Download product catalog PDF
Download the English product catalog PDF for HT-DG480A1 Industrial Dehumidifier | 480 L/D Moisture Control. Use it for model comparison, technical review and inquiry preparation.
Use the exact model, voltage and installation conditions for project selection.
Confirm the published specifications, then add this product to your quote list.Product inquiry