| Model | Dehumidification | Voltage | Input power | Airflow | Size |
|---|---|---|---|---|---|
| HT-15NE | 10kg/h | 380V3N-50Hz | 3.7 | 2800 | 770x470x1600 |
Project confirmation: Confirm the exact model, electrical supply, operating environment, installation space and required documents before final order approval.
Best-fit Applications
This model suits rooms where humidity has to come down but the temperature must stay put: a process room, a lab, or a storage area holding temperature-sensitive goods. A standard dehumidifier cools the air as it dries it, which is not always wanted; this unit keeps temperature stable while removing moisture.
It runs on three-phase 380 V and removes 10 kg/h, with 2,800 m³/h of circulation to distribute dry air. Because it holds temperature as it works, it is the right choice where a cold draught or a temperature drop would spoil the product or the process.
- Process rooms: removes moisture without shifting the room temperature.
- Laboratories: keeps humidity under control where temperature must stay stable.
- Sensitive storage: protects goods that react to both damp and temperature change.
Selection guide
- Humidity and temperature: confirm both targets, since this unit holds temperature steady.
- Capacity in kg/h: check the removal rate against the room load.
- Supply: three-phase 380 V, planned for 3.7 kW.
- Air path: use the 2,800 m³/h circulation across the room.
- Drain route: continuous drainage for long running periods.
What NOT to Buy
| Situation | Risk | Better action |
|---|---|---|
| Temperature drop wanted | This unit holds temperature, it does not cool. | Use a standard dehumidifier instead. |
| Load above capacity | The unit will miss the humidity target. | Confirm the load against 10 kg/h. |
| Single-phase site | It needs three-phase 380 V. | Check the supply before ordering. |
| No drain plan | Continuous running needs drainage. | Arrange the drain route. |
Industrial Dehumidifier Buyer Checklist
Use the source-backed product information on this page as the starting point, then confirm site conditions before approving the final model.
- Target humidity and the temperature that must be held
- Removal rate against 10 kg/h
- Three-phase 380 V supply for 3.7 kW
- Continuous drain and clearance for a tall cabinet
HT-15NE is positioned for temperature-controlled industrial dehumidification; confirm capacity, drainage and site humidity load before final selection.
Core Engineering Features
HT-15NE Constant Temperature Dehumidifier | Industrial Humidity Contro set against the published values on this page. Every point below is taken from this model’s own data.
Quality Assurance & Warranty
Dehumidifier orders are verified at the factory before shipping, because a unit sized for a humidity target is only useful if it arrives working to that target.
Applied to this model: Capacity 10kg/h, Power 380V3N-50Hz. These checks are run against that specification before the unit ships.
OEM/ODM & Supply Options
For distributors and contractors working on moisture-control projects, the supply side adapts to your market instead of one fixed cabinet build.
For this model (Capacity 10kg/h, Power 380V3N-50Hz), the OEM route can start from that base specification rather than a blank sheet.
Documents & Compliance
This dehumidifier series is supported by Linggong Electric CE LVD/EMC and RoHS documentation for the listed HT, LG, HT-DG, LG-DG and LG-D dehumidifier model ranges.
- CE AttestationM.2025.206.C118876
- Technical FilesDTCF0509-LVD/EMC and DTCF0509-ROHS
- ApplicantZhejiang Linggong Electric Appliance Co., Ltd.
Scope boundary: use these documents for the dehumidifier model families listed in the certificates. The DTS1250 SGS performance report is not used here because its applicant/model scope does not match Linggongshare pages.
FAQ
How do I choose dehumidifier capacity?
This is a constant-temperature unit, so confirm both the humidity target and the temperature that must be held, then check the load against 10 kg/h. The 2,800 m³/h circulation then covers the room.
Can it run continuously?
Yes, on three-phase 380 V. Because it holds temperature while removing moisture, it suits continuous duty in process and storage rooms where a temperature drop is not acceptable. Clean the filter on schedule, keep the 2,800 m³/h air path clear and the drain free. Because the unit holds temperature as it works, do not confuse its behaviour with a standard cooling dehumidifier during fault-finding.
Download product catalog PDF
Download the English product catalog PDF for HT-15NE Industrial Dehumidifier | 10 kg/h Moisture Control. Use it for model comparison, technical review and inquiry preparation.
Use the exact model, voltage and installation conditions for project selection.
Confirm the published specifications, then add this product to your quote list.Product inquiry