HT-DG240A1 Industrial Dehumidifier | 240 L/D Moisture Control
240 industrial dehumidifier for moisture-control projects
- MOISTURE CONTROL
- 240 industrial dehumidifier for moisture-control projects
- POWER CHECK
- AC380V/50Hz; confirm exact circuit before ordering
- SELECTION NOTE
- Confirm room load, target humidity and drainage plan before quotation
HT-DG240A1 Industrial Dehumidifier | 240 L/D High-Capacity Moisture Control
HT-DG240A1 is an industrial dehumidifier option for warehouses, production rooms, storage areas and equipment spaces where moisture control affects comfort, corrosion risk, product storage or process stability.
Selection flow
Project flow
Application fit
Where this model fits, and what to verify first
Source-backed Technical Parameters
| Source model | PIM/page model | Dehumidification | Voltage | Input power | Airflow | Size | Confidence |
|---|---|---|---|---|---|---|---|
| HT-DG240A1 | LG-DG240A1 | 240 | AC380V/50Hz | 2600 | 2200 | 705x410x1600 | high |
Source notes:
HT-DG240A1 → LG-DG240A1: high confidence, source page uploaded_image_05; Source uses HT-DG240A1; mapped to existing LG-DG240A1 variant with mismatch note.
Legacy page note: Original page content was backed up before this source-backed UI v4 update.
Best-fit Applications
This unit is built for spaces where moisture is a constant problem: a full warehouse, a large production hall, or a storage area where damp air threatens stock and equipment. The 2,200 m³/h of circulation is what lets dry air reach across a big volume rather than pooling near the machine.
It runs on three-phase 380 V at 2,600 W, so the supply and circuit have to be planned. For a load this size, continuous drainage is not optional: a large unit produces condensate steadily whenever it runs.
- Warehouses: holds humidity down across a large storage volume all day.
- Production halls: protects processes and equipment in a humid, busy space.
- Heavy-load stores: where moisture threatens cartons, metal and finished goods.
Selection guide
- Moisture load: confirm litres per day against 240 L/D with margin.
- Supply: three-phase 380 V, circuit planned for 2,600 W.
- Air path: use the 2,200 m³/h circulation across the whole space.
- Drain route: continuous drainage is essential at this capacity.
- Placement: allow clearance around a tall floor-standing cabinet.
What NOT to Buy
| Situation | Risk | Better action |
|---|---|---|
| Room too small | A 2,200 m³/h unit is oversized for a small room. | Match capacity to the load and volume. |
| No three-phase power | This model will not run on 220 V. | Check the HT-DG138A1 or 158A-B instead. |
| Load not calculated | Guessing at capacity wastes money either way. | Confirm litres per day first. |
| No drain plan | A continuous unit needs a dependable drain. | Arrange drainage before installation. |
Industrial Dehumidifier Buyer Checklist
Use the source-backed product information on this page as the starting point, then confirm site conditions before approving the final model.
- Daily moisture load against 240 L/D
- Three-phase 380 V supply and circuit for 2,600 W
- Circulation path for 2,200 m³/h
- Continuous drain, plus clearance for a tall cabinet
HT-DG240A1 is positioned for large workshops, warehouses and storage moisture control; confirm capacity, drainage and site humidity load before final selection.
Core Engineering Features
HT-DG240A1 Industrial Dehumidifier | 240 L/D High-Capacity Moisture Co set against the published values on this page. Every point below is taken from this model’s own data.
Quality Assurance & Warranty
Dehumidifier orders are verified at the factory before shipping, because a unit sized for a humidity target is only useful if it arrives working to that target.
Applied to this model: Capacity 240 L/D, Power AC380V/50Hz. These checks are run against that specification before the unit ships.
OEM/ODM & Supply Options
For distributors and contractors working on moisture-control projects, the supply side adapts to your market instead of one fixed cabinet build.
For this model (Capacity 240 L/D, Power AC380V/50Hz), the OEM route can start from that base specification rather than a blank sheet.
Documents & Compliance
This dehumidifier series is supported by Linggong Electric CE LVD/EMC and RoHS documentation for the listed HT, LG, HT-DG, LG-DG and LG-D dehumidifier model ranges.
- CE AttestationM.2025.206.C118876
- Technical FilesDTCF0509-LVD/EMC and DTCF0509-ROHS
- ApplicantZhejiang Linggong Electric Appliance Co., Ltd.
Scope boundary: use these documents for the dehumidifier model families listed in the certificates. The DTS1250 SGS performance report is not used here because its applicant/model scope does not match Linggongshare pages.
FAQ
How do I choose dehumidifier capacity?
Estimate the daily moisture load and check it against 240 L/D. This is a large three-phase unit, so it suits a warehouse or big hall rather than a small room, and the 2,200 m³/h airflow has to fit the space.
Can it run continuously?
Yes, and it is designed for it. At 2,600 W on three-phase 380 V with 2,200 m³/h, continuous duty needs a reliable drain and a properly sized circuit. Keep the air path and the drain clear, clean the filter on schedule, and allow service access around a tall cabinet. At this capacity the unit runs long hours, so the drain is the item to watch.
Why do some model names differ?
Some source rows use HT model codes while the website/PIM layer may use LG model codes. Both are shown to avoid silent normalization.
Download product catalog PDF
Download the English industrial dehumidifier catalog for product-family overview and technical review. Confirm the exact HT model, voltage and installation conditions with our team before relying on it for project selection.
Use the exact model, voltage and installation conditions for project selection.
Confirm the published specifications, then add this product to your quote list.Product inquiry