HT-DG138A1 Industrial Dehumidifier | 108 L/D Moisture Control
108 industrial dehumidifier for moisture-control projects
- MOISTURE CONTROL
- 108 industrial dehumidifier for moisture-control projects
- POWER CHECK
- AC220V-50Hz; confirm exact circuit before ordering
- SELECTION NOTE
- Confirm room load, target humidity and drainage plan before quotation
HT-DG138A1 Industrial Dehumidifier | 108 L/D Moisture Control
HT-DG138A1 is an industrial dehumidifier option for warehouses, production rooms, storage areas and equipment spaces where moisture control affects comfort, corrosion risk, product storage or process stability.
Selection flow
Project flow
Application fit
Where this model fits, and what to verify first
Source-backed Technical Parameters
| Source model | PIM/page model | Dehumidification | Voltage | Input power | Airflow | Size | Confidence |
|---|---|---|---|---|---|---|---|
| HT-DG138A1 | LG-DG138A1 | 108 | AC220V-50Hz | 1300 | 550 | 410x385x915 | high |
Source notes:
HT-DG138A1 → LG-DG138A1: high confidence, source page uploaded_image_09; Uploaded image 09 OCR; mapped to existing LG-DG138A1.
Legacy page note: Original page content was backed up before this source-backed UI v4 update.
Best-fit Applications
This model suits bigger rooms that still run on single-phase power: a large workshop, a storage hall or a production area where the daily moisture load is well above 90 L/D. The 550 m³/h airflow helps carry dry air further across the space.
Because it is the highest-capacity single-phase unit, it avoids the cost of installing three-phase power while still handling a substantial room. Check the circuit for the 1,300 W draw and plan the drain for continuous running.
- Large workshops: keeps humidity under control where several work areas share one room.
- Storage halls: protects stock across a wider footprint than a medium unit can reach.
- Production rooms: holds stable conditions where damp air would affect output.
Selection guide
- Moisture load: confirm litres per day, including moisture from processes and people.
- Air distribution: match the 550 m³/h circulation to the room shape.
- Drain route: plan continuous drainage, since this unit is built for long runs.
- Supply: single-phase 220 V, circuit sized for 1,300 W.
- Temperature: verify performance in cooler rooms before final selection.
What NOT to Buy
| Situation | Risk | Better action |
|---|---|---|
| Hall larger than the load allows | Even 108 L/D has a limit in a very big space. | Compare the three-phase models before committing. |
| Area-based sizing | Floor area hides the real moisture load. | Work out litres per day first. |
| Tank-only drainage | Frequent filling interrupts long runs. | Plan a gravity or pump drain. |
| Cool room ignored | Capacity falls at low temperature. | Confirm the working range. |
Industrial Dehumidifier Buyer Checklist
Use the source-backed product information on this page as the starting point, then confirm site conditions before approving the final model.
- Daily moisture load including process gains
- Room volume against the 550 m³/h circulation
- Continuous drain method
- 220 V circuit sized for 1,300 W
HT-DG138A1 is positioned for mid-capacity industrial moisture control; confirm capacity, drainage and site humidity load before final selection.
Core Engineering Features
HT-DG138A1 Industrial Dehumidifier | 108 L/D Moisture Control set against the published values on this page. Every point below is taken from this model’s own data.
Quality Assurance & Warranty
Dehumidifier orders are verified at the factory before shipping, because a unit sized for a humidity target is only useful if it arrives working to that target.
Applied to this model: Capacity 108 L/D, Power AC220V-50Hz. These checks are run against that specification before the unit ships.
OEM/ODM & Supply Options
For distributors and contractors working on moisture-control projects, the supply side adapts to your market instead of one fixed cabinet build.
For this model (Capacity 108 L/D, Power AC220V-50Hz), the OEM route can start from that base specification rather than a blank sheet.
Documents & Compliance
This dehumidifier series is supported by Linggong Electric CE LVD/EMC and RoHS documentation for the listed HT, LG, HT-DG, LG-DG and LG-D dehumidifier model ranges.
- CE AttestationM.2025.206.C118876
- Technical FilesDTCF0509-LVD/EMC and DTCF0509-ROHS
- ApplicantZhejiang Linggong Electric Appliance Co., Ltd.
Scope boundary: use these documents for the dehumidifier model families listed in the certificates. The DTS1250 SGS performance report is not used here because its applicant/model scope does not match Linggongshare pages.
FAQ
How do I choose dehumidifier capacity?
Work out the daily moisture load and check it against 108 L/D. This is the highest-capacity single-phase model, so it fits larger rooms, but the load and the 550 m³/h circulation still set the answer.
Can it run continuously?
Yes. At 1,300 W on 220 V it can run continuously, provided the drain route and the circuit are planned for it. Confirm the load stays within 108 L/D so it is not running flat out. Keep both the air path and the drain clear, and clean the filter on schedule. As the strongest single-phase unit it runs long hours, so maintenance access matters from the first installation.
Why do some model names differ?
Some source rows use HT model codes while the website/PIM layer may use LG model codes. Both are shown to avoid silent normalization.
Download product catalog PDF
Download the English industrial dehumidifier catalog for product-family overview and technical review. Confirm the exact HT model, voltage and installation conditions with our team before relying on it for project selection.
Use the exact model, voltage and installation conditions for project selection.
Confirm the published specifications, then add this product to your quote list.Product inquiry