🎯 Find the right ventilation product
Ask our HVAC AI — get specs & recommendation in seconds

BPT-10-23S Ceiling Exhaust Fan | Quiet Bathroom Ventilation

BPT-10-23S Ceiling Exhaust Fan for noise-sensitive environments needing quiet, balanced ceiling ventilation

PROJECT FIT
BPT-10-23S Ceiling Exhaust Fan for noise-sensitive environments needing quiet, balanced ceiling ventilation
PERFORMANCE RANGE
Single model · quiet ceiling exhaust · compact panel design for standard ceiling openings
Compact ceiling exhaust

BPT-10-23S: A Quiet Ceiling Exhaust for Bathrooms and Small Rooms

This ceiling exhaust fan fits a 300 × 300 mm opening and a 100 mm duct, a straightforward size choice. Use it in bathrooms, washrooms and compact rooms where the air path goes through the ceiling and quiet operation is important. At 41 dB(A) it stays in the background while keeping air fresh.

Panel size
300 × 300 mm
Duct
100 mm
Airflow
250 m³/h
Noise
41 dB(A)

Need help matching your opening? Ask for product selection, or compare ceiling models below. For bulk orders, contact us for project pricing.

Product parameters

BPT-10-23S Ceiling Exhaust Fan Specifications

Reference dimensions and performance data for the BPT-10-23S ceiling exhaust fan model.

BPT-10-23S ceiling exhaust fan size drawing showing A B C D E F ΦD and hole size dimensions
Use the size drawing together with the dimensions table to check panel size, duct diameter and installation depth for quote review.
BPT-10-23S dimensions
Model A B C D E F ΦD Hole Size(mm)
BPT-10-23S 300 300 100 200 270 300 100 300X300

For buyers, this means a 300 × 300 mm panel, 300 × 300 mm opening reference and 100 mm duct planning for compact ceiling exhaust installation.

Performance
Model Use level Buyer meaning
BPT-10-23S 250 m³/h compact exhaust 200V~50Hz, 30 W, 250 m³/h airflow, 150 Pa static pressure and 41 dB(A) noise for compact bathroom or room ceiling ventilation.
Demand fit

What need does this model help solve

Best use

Use this model for compact bathroom and room ceiling ventilation where a 300 × 300 mm panel and 100 mm duct route fit the project.

Selection factors

The 250 m³/h airflow and 150 Pa pressure help screen fit for final selection for short-duct compact-room exhaust.

Avoid

Do not use this model for long high-resistance duct runs or projects that need a larger airflow class.

Selection guide

Selection guide

1. Define room need

Bathroom, utility room, commercial restroom, workshop or sidewall exhaust.

2. Confirm air route

Ceiling duct, direct wall route, shutter opening or panel installation.

3. Match performance

Confirm airflow, noise target, duct length and bends.

4. Request confirmation

Send model, quantity, voltage and destination for selection support.

Fit check

Compare the options

Use the official Exhaust Fans Collection Hub when comparing ceiling, wall, EC bathroom and shutter exhaust fan options.

Core Engineering Features

BPT-10-23S: A Quiet Ceiling Exhaust for Bathrooms and Small Rooms set against the published values on this page. Every point below is taken from this model’s own data.

A300
B300
C100
D200
E270
F300

Quality Assurance & Warranty

Fan orders are checked at the factory before shipping, because published airflow and pressure only hold if the delivered unit matches its table row.

Applied to this model: A 300, B 300. These checks are run against that specification before the unit ships.

Airflow and pressure checkChecks cover motor start-up, impeller balance, airflow and static pressure verification, noise review and model-to-table parameter matching.
Documented complianceCE, RoHS and related files cover the listed fan families; see the documents section below.
Warranty supportWarranty for fan orders is confirmed with the quotation for your destination market.
Service parts for fansImpellers, motor capacitors, mounting brackets and common service items.

OEM/ODM & Supply Options

For distributors and contractors working on ventilation projects, the supply side adapts to your market instead of one fixed fan build.

For this model (A 300, B 300), the OEM route can start from that base specification rather than a blank sheet.

OEM/ODMBadging, packaging and control options for fan orders, including branded cartons and manual inserts.
Airflow and pressure variantsModel selection, motor power and voltage options are reviewed against your duct calculation.
Voltage & plug optionsVoltage and plug configuration for this product line can be reviewed during quotation.
Documentation & bulk supplyCatalogues, technical sheets, available certificates, volume pricing and distributor programs for this product line.
Order quantity & lead timeMinimum order quantity, sampling and production lead time are confirmed per model and order volume — see the B2B supply page for how sourcing enquiries are handled.

Documents & Compliance

Download the metal exhaust fan datasheet used for the technical values on this page, and review the relevant compliance documents.

Confirm the exact model, destination-market requirements and current documentation before quotation or project documentation.

Frequently asked questions

How do I choose this model?

Start from the installation route and room use, then confirm the exact model datasheet or database row.

Can I use generic fan values?

No. Use only confirmed source values for airflow, noise, power and dimensions.

What should I send for quotation?

Send room type, opening size, duct path, airflow target, voltage, quantity and destination.

Product inquiry

Confirm the published specifications, then add this product to your quote list.