🎯 Find the right ventilation product
Ask our HVAC AI — get specs & recommendation in seconds

Alum Panel Ceiling Fan

Alum Panel Ceiling Fan for clean ceiling-mounted room ventilation with aluminum panel finish

PROJECT FIT
Alum Panel Ceiling Fan for clean ceiling-mounted room ventilation with aluminum panel finish
PERFORMANCE RANGE
Single model · 180 m³/h · 200V~50Hz · static pressure 98 Pa · noise 42 dB · 300×300 mm panel
Exhaust fan selection overview

Alum Panel Ceiling Fan quick check and model confirmation

Alum Panel Ceiling Fan fits clean ceiling-mounted room ventilation where the visible panel, opening size, duct route and exact KC/APC model row need to match for quote review.

Project fitceiling / panel exhaust
Applicationclean ceiling-mounted room ventilation
Project detailsConfirm the KC/APC model row before quoting airflow, opening size or quantity
Selection rule

Do not approve the model from the product name alone. Confirm mounting route, duct path, opening size, airflow/noise target and power supply.

Performance & dimensions

Alum Panel Ceiling Fan dimensions
Model A (mm) B (mm) C (mm) ΦD (mm) D (mm) E (mm)
BPT10-23 300 300 100 98 363 237
Alum Panel Ceiling Fan performance
Model Voltage/Frequency Power (W) Airflow (m³/h) Static Pressure (Pa) Noise dB(A) Weight (kg) Duct Φ (mm) Panel (mm) Hole (mm)
BPT-10-23 200V~50Hz 30 180 98 42 2.1 100 300×300 300×300
Application fit

Where this exhaust fan fits

Best use

clean ceiling-mounted room ventilation.

Selection factors

Confirm the KC/APC model row before quoting airflow, opening size or quantity.

Avoid

Do not select only by product photo or generic category name.

Selection guide

Selection guide

1. Define room need

Bathroom, utility room, commercial restroom, workshop or sidewall exhaust.

2. Confirm air route

Ceiling duct, direct wall route, shutter opening or panel installation.

3. Match performance

Confirm airflow, noise target, duct length and bends.

4. Request confirmation

Send model, quantity, voltage and destination for selection support.

Fit check

Compare the options

Use the official Exhaust Fans Collection Hub when comparing ceiling, wall, EC bathroom and shutter exhaust fan options.

Frequently asked questions

How do I choose this model?

Start from the installation route and room use, then confirm the exact model datasheet or database row.

Can I use generic fan values?

No. Use only confirmed source values for airflow, noise, power and dimensions.

What should I send for quotation?

Send room type, opening size, duct path, airflow target, voltage, quantity and destination.

Core Engineering Features

Alum Panel Ceiling Fan quick check and model confirmation set against the published values on this page. Every point below is taken from this model’s own data.

Project fitceiling / panel exhaust
Applicationclean ceiling-mounted room ventilation
Project detailsConfirm the KC/APC model row before quoting airflow, opening size or quantity
A (mm)300
B (mm)300
C (mm)100

Quality Assurance & Warranty

Fan orders are checked at the factory before shipping, because published airflow and pressure only hold if the delivered unit matches its table row.

Applied to this model: Project fit ceiling / panel exhaust, Application clean ceiling-mounted room ventilation. These checks are run against that specification before the unit ships.

Airflow and pressure checkChecks cover motor start-up, impeller balance, airflow and static pressure verification, noise review and model-to-table parameter matching.
Documented complianceCE, RoHS and related files cover the listed fan families; see the documents section below.
Warranty supportWarranty for fan orders is confirmed with the quotation for your destination market.
Service parts for fansImpellers, motor capacitors, mounting brackets and common service items.

OEM/ODM & Supply Options

For distributors and contractors working on ventilation projects, the supply side adapts to your market instead of one fixed fan build.

For this model (Project fit ceiling / panel exhaust, Application clean ceiling-mounted room ventilation), the OEM route can start from that base specification rather than a blank sheet.

OEM/ODMBadging, packaging and control options for fan orders, including branded cartons and manual inserts.
Airflow and pressure variantsModel selection, motor power and voltage options are reviewed against your duct calculation.
Voltage & plug optionsVoltage and plug configuration for this product line can be reviewed during quotation.
Documentation & bulk supplyCatalogues, technical sheets, available certificates, volume pricing and distributor programs for this product line.
Order quantity & lead timeMinimum order quantity, sampling and production lead time are confirmed per model and order volume — see the B2B supply page for how sourcing enquiries are handled.

Documents & Compliance

KC-series CE documentation is available for matched source models.

Scope: For KC-series inline / ceiling fan source scope. Match the exact model and variant before compliance use.

Do not apply these documents to unrelated fan models; confirm exact model code for export paperwork.

Where is the Alum Panel Ceiling Fan used?

It is used in bathrooms, washrooms, apartments, offices and small rooms where exhaust air can be routed above the ceiling and a clean panel-style appearance is preferred.

How is it different from a wall-mounted exhaust fan?

A ceiling fan fits overhead duct layouts and keeps the fan face on the ceiling. A wall-mounted fan is better when the room can discharge directly through an exterior wall.

What should be confirmed before choosing this fan?

Confirm the ceiling opening, mounting depth, duct length, number of bends, power supply and target airflow for the room.

Product inquiry

Confirm the published specifications, then add this product to your quote list.