Single Room HRV VT501-WiFi
VT501 / VT501-WF / VT501-MS for single-room fresh-air ventilation with heat recovery and optional smart control
- PROJECT FIT
- Compact wall-install · operating modes Sleep / I / II / III
Why VT501-WiFi for single-room fresh air
Ceramic heat exchanger
Recovers up to 95% of thermal energy, so fresh air arrives without throwing away conditioned air.
Remote or WiFi operation
Choose the standard remote model or the WiFi model with Tuya app control, CO2 monitoring and automation.
HEPA + activated carbon
Multi-stage filtration reduces pollen, dust, PM and outdoor odors before supply air enters the room.
Under 30 dB operation
A brushless DC motor and sound-sealed design suit bedrooms, nurseries and home offices.
Fresh, exhaust and cycle
Fresh Air, Exhaust and 65-second Cycle modes give practical control over room ventilation.
Single-hole wall install
No central ductwork required. It installs through an exterior wall with a telescopic duct and room-side panel.
Source-backed VT501-WiFi HRV parameters
Published source: KCVENTS VT501 technical table.
| Parameter | Sleep | I | II | III |
|---|---|---|---|---|
| Installation tube / wall thickness | 250–500 mm | |||
| Voltage | 12VDC or 100–240V 50–60Hz | |||
| Ventilator Total Power (W) | 2.5 | 3.0 | 4.5 | 8.5 |
| Ventilator Current (A) | 0.025 | 0.030 | 0.045 | 0.070 |
| Airflow (m³/h) | 20 | 48 | 54 | 60 |
| Speed (RPM) | 630 | 1100 | 1600 | 2200 |
| Noise Level (dB(A)) | 12 | 20.0 | 24.0 | 30.0 |
| Transported Air Temperature | -20°C (-4°F) to +50°C (122°F) | |||
| Heat Exchange Efficiency | up to 95% | |||
| Heat Exchanger Core | Ceramic |
How to select the right VT501 version
VT501 comes in three control versions for single-room fresh-air ventilation with heat recovery: VT501 (base), VT501-WF (WiFi) and VT501-MS.
Pick the airflow stage
Four stages (20 / 48 / 54 / 60 m³/h) suit bedrooms, offices and small rooms. Match the stage to room size and occupancy.
Check wall / tube depth
The installation tube fits 250–500 mm wall thickness. Measure the actual opening before ordering.
Choose the control
Base remote control or WiFi version with app control. Confirm which is required for the project.
Where this single-room HRV fits
VT501 / VT501-WF / VT501-MS is a room-by-room ventilation route for bedrooms, offices and other spaces where a central ventilation system is not the selected installation approach.
Fit boundary: For whole-building balanced ventilation, confirm whether a central ERV or multi-room design is required.
Frequently asked questions
Can this replace a central ERV?
It is mainly a room-by-room retrofit option. For whole-building balanced ventilation, confirm a central ERV or multi-room design.
What must be checked before order?
See the order checklist above: control version, wall thickness, airflow stage, power supply and quantity.
Are the listed values final for every version?
No. The values are source-backed from PDF p.6; confirm the exact version and order configuration for quote review.
Certification & quality assurance
100% pre-shipment inspection
Every batch undergoes functional and dimensional checks so that every unit arrives ready for installation: ceramic core fit, filter placement, remote and WiFi response, airflow mode switching, wall tube sizing and noise verification.
Hardware warranty support
In the rare event of a material defect or mechanical failure under standard operation, a straightforward replacement service protects your project timeline.
Before you order: confirm checklist
- Control version: VT501 (remote) or VT501-WF (WiFi)
- Wall thickness and installation tube length (250–500 mm)
- Airflow stage (Sleep / I / II / III) and operating mode
- Power supply and quantity
Core Engineering Features
Why VT501-WiFi for single-room fresh air set against the published values on this page. Every point below is taken from this model’s own data.
Quality Assurance & Warranty
Fan orders are checked at the factory before shipping, because published airflow and pressure only hold if the delivered unit matches its table row.
Applied to this model: Pick the airflow stage Four stages (20 / 48 / 54 / 60 m³/h) suit bedrooms, offices and small rooms. Match the stage to room size and occupancy., Check wall / tube depth The installation tube fits 250–500 mm wall thickness. Measure the actual opening before ordering.. These checks are run against that specification before the unit ships.
OEM/ODM & Supply Options
For distributors and contractors working on ventilation projects, the supply side adapts to your market instead of one fixed fan build.
For this model (Pick the airflow stage Four stages (20 / 48 / 54 / 60 m³/h) suit bedrooms, offices and small rooms. Match the stage to room size and occupancy., Check wall / tube depth The installation tube fits 250–500 mm wall thickness. Measure the actual opening before ordering.), the OEM route can start from that base specification rather than a blank sheet.
Related products
Adjacent models customers compare before deciding. Open a card to see its own published specifications.
Product inquiry
Have your control version, wall thickness, airflow stage and quantity ready, then add this product to your quote list.
Download the VT501 catalog