🎯 Find the right ventilation product
Ask our HVAC AI — get specs & recommendation in seconds

KTJ Cabinet Fan Series

KTJ cabinet fan series for office, workshop, warehouse, and general commercial ventilation

PROJECT FIT
KTJ cabinet fan series for office, workshop, warehouse, and general commercial ventilation
PERFORMANCE RANGE
8 models · 2,000–20,000 m³/h · 220–380V · static pressure 250–550 Pa · low-noise design
Cabinet fan selection

Cabinet Fan Selection Snapshot

KTJ cabinet fan series for office, workshop, warehouse and general commercial ventilation with filtered cabinet airflow and low-noise operation. Check the model table for airflow range, static pressure, and dimensions before specifying.

Source: CHIC GROUP HVAC 2026 catalogue (p.27-28). High-confidence PIM rows from Cabinet / Air Conditioning Fan Series.
Project fitKTJ cabinet fan series, 2,000-20,000 m3/h catalog range
Sample modelsKTJ23-20 / KTJ23-20D / KTJ23-26 / KTJ23-26D
Project detailsConfirm target airflow, duct route, static pressure, voltage, inlet/outlet opening, installation space and filter maintenance interval
Source note

Only high-confidence rows are shown. Unrelated smoke-exhaust models are excluded from this Cabinet/KTJ/DT batch.

Documented checks

High-confidence model checks

KTJ Cabinet Fan Series technical and selection table
Model Voltage Power W Airflow m³/h Static pressure Pa Noise dB(A) Outlet / filter size Source
KTJ23-20 380 250 2000 400 55 350×312 14
KTJ23-20D 220 250 2000 400 55 350×312 14
KTJ23-26 380 370 2600 420 56 430×312 14
KTJ23-26D 220 370 2600 420 56 430×312 14
KTJ23-31 380 550 3100 440 61 335×320 14
KTJ23-31D 220 550 3100 440 61 335×320 14
KTJ23-41 380 750 4100 460 65 550×380 14
KTJ23-41D 220 750 4100 460 65 550×380 14
Application fit

Where this cabinet fan fits

Cabinet fans are selected when a project needs enclosed airflow, easier service access and a cleaner installation than an open fan. For kitchen or high-resistance routes, static pressure and oil/filter access matter as much as airflow.

Use the model table as a starting point, then confirm duct resistance, opening size and maintenance clearance for final selection.

Typical buyer checks

  • Airflow and static pressure at working point
  • Voltage/frequency and motor protection requirement
  • Inlet/outlet opening and filter size
  • Inspection door, oil/water drain and cleaning access
Selection guide

Cabinet fan selection guide

1. Define duty

General ventilation, filtered cabinet airflow, kitchen exhaust or long duct/high-pressure route.

2. Match airflow + pressure

Do not choose by airflow alone; static pressure and duct losses decide the usable model.

3. Check installation

Confirm opening size, cabinet dimensions, mounting space and maintenance clearance.

4. Confirm model

Send duct route, airflow target, voltage and site photos for quote review.

Compare

KTJ / KTJ-G / DT positioning

KTJ is suited to general cabinet ventilation, KTJ-G is better for filter/oil-management cabinet use, and DT high-pressure cabinet fans are better for longer or higher-resistance duct routes. HTFC smoke-exhaust products are a separate family and are not merged into this table.

Core Engineering Features

Cabinet Fan Selection Snapshot set against the published values on this page. Every point below is taken from this model’s own data.

Project fitKTJ cabinet fan series, 2,000-20,000 m3/h catalog range
Sample modelsKTJ23-20 / KTJ23-20D / KTJ23-26 / KTJ23-26D
Project detailsConfirm target airflow, duct route, static pressure, voltage, inlet/outlet opening, installation space and filter maintenance interval
Voltage380
Power W250
Airflow m³/h2000

Quality Assurance & Warranty

Fan orders are checked at the factory before shipping, because published airflow and pressure only hold if the delivered unit matches its table row.

Applied to this model: Project fit KTJ cabinet fan series, 2,000-20,000 m3/h catalog range, Sample models KTJ23-20 / KTJ23-20D / KTJ23-26 / KTJ23-26D. These checks are run against that specification before the unit ships.

Airflow and pressure checkChecks cover motor start-up, impeller balance, airflow and static pressure verification, noise review and model-to-table parameter matching.
Documented complianceCE, RoHS and related files cover the listed fan families; see the documents section below.
Warranty supportWarranty for fan orders is confirmed with the quotation for your destination market.
Service parts for fansImpellers, motor capacitors, mounting brackets and common service items.

OEM/ODM & Supply Options

For distributors and contractors working on ventilation projects, the supply side adapts to your market instead of one fixed fan build.

For this model (Project fit KTJ cabinet fan series, 2,000-20,000 m3/h catalog range, Sample models KTJ23-20 / KTJ23-20D / KTJ23-26 / KTJ23-26D), the OEM route can start from that base specification rather than a blank sheet.

OEM/ODMBadging, packaging and control options for fan orders, including branded cartons and manual inserts.
Airflow and pressure variantsModel selection, motor power and voltage options are reviewed against your duct calculation.
Voltage & plug optionsVoltage and plug configuration for this product line can be reviewed during quotation.
Documentation & bulk supplyCatalogues, technical sheets, available certificates, volume pricing and distributor programs for this product line.
Order quantity & lead timeMinimum order quantity, sampling and production lead time are confirmed per model and order volume — see the B2B supply page for how sourcing enquiries are handled.

Documents & Compliance

Download the cabinet fan datasheet used for the technical values on this page, and review the relevant compliance documents.

Confirm the exact model, destination-market requirements and current documentation before quotation or project documentation.

Frequently asked questions

Can I select by airflow only?

No. Cabinet fan selection must include static pressure, duct route, elbows, inlet/outlet size and maintenance access.

Are all models listed?

No. The table shows high-confidence sample rows from the matched PDF/PIM source. Ask for the exact model datasheet before final order.

Is HTFC included in this page?

No. HTFC smoke-exhaust cabinet centrifugal fans require separate source handling and should not be mixed with KTJ/DT cabinet fan tables.

Product inquiry

Confirm the published specifications, then add this product to your quote list.

model

, , , , , , ,