Cabinet Box Fan
KTJ-G cabinet box fan with filter for commercial kitchens and oily exhaust requiring washable access
- PROJECT FIT
- KTJ-G cabinet box fan with filter for commercial kitchens and oily exhaust requiring washable access
- PERFORMANCE RANGE
- 3 models · 2,000–3,100 m³/h · 220–380V · static pressure 320–480 Pa · integrated filter
Cabinet Fan Selection Snapshot
KTJ-G cabinet box fan range for commercial kitchens, oily exhaust pre-filtering and compact cabinet ventilation requiring washable access and stable pressure. Check the model table for airflow, static pressure, and dimensions before specifying.
Only high-confidence rows are shown. Unrelated smoke-exhaust models are excluded from this Cabinet/KTJ/DT batch.
High-confidence model checks
| Model | Voltage | Power W | Airflow m³/h | Static pressure Pa | Noise dB(A) | Outlet / filter size | Source |
|---|---|---|---|---|---|---|---|
| KTJ22-20DG | 220 | 250 | 2000 | 430 | 55 | 270×265 | 15 |
| KTJ22-20G | 380 | 250 | 2000 | 430 | 55 | 270×265 | 15 |
| KTJ23-31DG | 220 | 550 | 3100 | 440 | 61 | 335×320 | 15 |
| KTJ23-31G | 380 | 550 | 3100 | 440 | 61 | 335×320 | 15 |
| KTJ23-41DG | 220 | 750 | 4100 | 460 | 65 | 335×320 | 15 |
Where this cabinet fan fits
Cabinet fans are selected when a project needs enclosed airflow, easier service access and a cleaner installation than an open fan. For kitchen or high-resistance routes, static pressure and oil/filter access matter as much as airflow.
Use the model table as a starting point, then confirm duct resistance, opening size and maintenance clearance for final selection.
- Airflow and static pressure at working point
- Voltage/frequency and motor protection requirement
- Inlet/outlet opening and filter size
- Inspection door, oil/water drain and cleaning access
Cabinet fan selection guide
General ventilation, filtered cabinet airflow, kitchen exhaust or long duct/high-pressure route.
Do not choose by airflow alone; static pressure and duct losses decide the usable model.
Confirm opening size, cabinet dimensions, mounting space and maintenance clearance.
Send duct route, airflow target, voltage and site photos for quote review.
KTJKTJ-GDT positioning
KTJ is suited to general cabinet ventilation, KTJ-G is better for filter/oil-management cabinet use, and DT high-pressure cabinet fans are better for longer or higher-resistance duct routes. HTFC smoke-exhaust products are a separate family and are not merged into this table.
Core Engineering Features
Cabinet Fan Selection Snapshot set against the published values on this page. Every point below is taken from this model’s own data.
Quality Assurance & Warranty
Fan orders are checked at the factory before shipping, because published airflow and pressure only hold if the delivered unit matches its table row.
Applied to this model: Project fit KTJ-G cabinet box fan with filter cabinet, Sample models KTJ22-20DGKTJ22-20GKTJ23-31DGKTJ23-31G. These checks are run against that specification before the unit ships.
OEM/ODM & Supply Options
For distributors and contractors working on ventilation projects, the supply side adapts to your market instead of one fixed fan build.
For this model (Project fit KTJ-G cabinet box fan with filter cabinet, Sample models KTJ22-20DGKTJ22-20GKTJ23-31DGKTJ23-31G), the OEM route can start from that base specification rather than a blank sheet.
Documents & Compliance
Download the cabinet fan datasheet used for the technical values on this page, and review the relevant compliance documents.
Confirm the exact model, destination-market requirements and current documentation before quotation or project documentation.
View all certifications and compliance documents by product scope
Frequently asked questions
Can I select by airflow only?
No. Cabinet fan selection must include static pressure, duct route, elbows, inlet/outlet size and maintenance access.
Are all models listed?
No. The table shows high-confidence sample rows from the matched PDF/PIM source. Ask for the exact model datasheet before final order.
Is HTFC included in this page?
No. HTFC smoke-exhaust cabinet centrifugal fans require separate source handling and should not be mixed with KTJ/DT cabinet fan tables.
Product inquiry
Confirm the published specifications, then add this product to your quote list.
| model |
|---|