🎯 Find the right ventilation product
Ask our HVAC AI — get specs & recommendation in seconds

1.5kW industrial centrifugal exhaust fan

1.5kW industrial centrifugal exhaust fan for heavy-duty exhaust ventilation in industrial facilities

PROJECT FIT
1.5kW industrial centrifugal exhaust fan for heavy-duty exhaust ventilation in industrial facilities
PERFORMANCE RANGE
1.5kW · centrifugal · industrial exhaust · heavy-duty

Selection Snapshot

1.5kW industrial centrifugal exhaust fan is positioned for industrial exhaust fan duty in pressure-duty ventilation projects. Industrial fan and industrial blower fan selection must follow the published model row rather than the page title, so confirm model fit, duty point and installation details for quote review.

Technical Parameters & Dimensions

4-72 series centrifugal fan technical parameters. This page presents the 1.5 kW model row (4-72-2.8-2-1.5KW); the full series is listed for project comparison.

4-72 Series Centrifugal Fan: Technical Parameters
Model & Power (kW)Speed (r/min)Air Volume (m³/h)Total Pressure (Pa)Efficiency (%)
4-72-2.8-2-1.5KW29001131~2356944~60669.3~69.3
4-72-3.2-4-1.1KW1450844~1758324~19869.3~69.3
4-72-3.2-2-2.2KW29001688~35171300~79269.3~69.3
4-72-3.6-4-1.1KW14501332~2634393~24774.2~74.3
4-72-3.6-2-3.0KW29002664~52681578~98974.2~74.3
4-72-4.0-4-1.10KW14502006~3700501~32977~77.5
4-72-4.0-2-5.5KW29004012~74192014~132077~77.5
4-72-4.5-4-1.1KW14502856~5281634~41677~77.5
4-72-4.5-2-7.5KW29005712~105622554~167377~77.5
4-72-5.0-4-2.24KW14503864~7728790~50277.6~77.6
4-72-5.0-2-15KW29007728~154553187~201977.6~77.6
4-72-6.0-4-4.0KW14506677~133531139~72477.6~77.6

Dimension drawing

4-72 centrifugal fan dimension drawing, overall and connection sizes
4-72 series dimension drawing: the size codes B/C/D/E/F/φ1/φ2/φ3 refer to the dimension table below.

Dimensions

4-72 Series Centrifugal Fan: Dimensions (mm)
Model NO.BCDEFφ1φ2φ3EF
4-72-2.8231225285250310203295330212273
4-72-3.2263289.5299.5319329252341380223311
4-72-3.6295.5317343317434317393420249249.5
4-72-4325280320340380400/460265380
4-72-4.5365320360380420450/520300430
4-72-5405350400430480500/560330475
4-72-6485420480500560600/370400570

Confirm the exact model, voltage, duct connection and installation clearance before final order approval.

Typical Applications

Project fit

Industrial exhaust / pressure duty.

Procurement note

Use this page as a starting point, then confirm the exact model and datasheet with Linggongshare.

Source note

Numeric parameters should be finalized only from source records or the latest datasheet.

Selection factors

  1. Share the target application and installation location.
  2. Confirm exact model, voltage/frequency and duty requirement.
  3. Check whether any certificates, drawings or special materials are required.
  4. Request a quotation and lead-time confirmation against the confirmed source record.

Compare the options

Compare this product by exact model, duty point, installation method, site environment, support documents and after-sales requirements, not by title alone.

Core Engineering Features

Selection Snapshot set against the published values on this page. Every point below is taken from this model’s own data.

Project fitIndustrial exhaust / pressure duty.
Procurement noteUse this page as a starting point, then confirm the exact model and datasheet with Linggongshare.
Source noteNumeric parameters should be finalized only from source records or the latest datasheet.
Speed (r/min)2900
Air Volume (m³/h)1131~2356
Total Pressure (Pa)944~606

Quality Assurance & Warranty

Fan orders are checked at the factory before shipping, because published airflow and pressure only hold if the delivered unit matches its table row.

Applied to this model: Project fit Industrial exhaust / pressure duty., Procurement note Use this page as a starting point, then confirm the exact model and datasheet with Linggongshare.. These checks are run against that specification before the unit ships.

Airflow and pressure checkChecks cover motor start-up, impeller balance, airflow and static pressure verification, noise review and model-to-table parameter matching.
Documented complianceCE, RoHS and related files cover the listed fan families; see the documents section below.
Warranty supportWarranty for fan orders is confirmed with the quotation for your destination market.
Service parts for fansImpellers, motor capacitors, mounting brackets and common service items.

OEM/ODM & Supply Options

For distributors and contractors working on ventilation projects, the supply side adapts to your market instead of one fixed fan build.

For this model (Project fit Industrial exhaust / pressure duty., Procurement note Use this page as a starting point, then confirm the exact model and datasheet with Linggongshare.), the OEM route can start from that base specification rather than a blank sheet.

OEM/ODMBadging, packaging and control options for fan orders, including branded cartons and manual inserts.
Airflow and pressure variantsModel selection, motor power and voltage options are reviewed against your duct calculation.
Voltage & plug optionsVoltage and plug configuration for this product line can be reviewed during quotation.
Documentation & bulk supplyCatalogues, technical sheets, available certificates, volume pricing and distributor programs for this product line.
Order quantity & lead timeMinimum order quantity, sampling and production lead time are confirmed per model and order volume — see the B2B supply page for how sourcing enquiries are handled.

Documents & Compliance

Technical values on this page follow the 4-72 series source table (this page presents 4-72-2.8-2-1.5KW). The CF-11 low-noise multiblade centrifugal fan catalog below covers the same fan family for related-model reference; review the relevant compliance documents as well.

Confirm the exact model, destination-market requirements and current documentation before quotation or project documentation.

Frequently Asked Questions

Can Linggongshare recommend a model directly?

Yes. Send the application, airflow or capacity target, installation constraints and power supply. The team can help narrow the model range.

Are all technical values final on this page?

For safety, final selection should be confirmed against the latest exact-model datasheet or source parameter record.

Product inquiry

Confirm the published specifications, then add this product to your quote list.