Mixed Flow Inline Fan | Compare DPT Noise and Pressure
Mixed-flow inline ventilation for duct routes. Compare published noise and static pressure by DPT model before selection.
- Project fit
- Mixed-flow inline ventilation for supply or exhaust duct routes.
- Model range
- 5 models · mixed-flow impeller · published noise and high-pressure inline duct performance
Start with the published model data
Compare the published airflow, static pressure and duct-size rows below. Final selection should match the installed duct route, voltage and quantity.
DPT model performance
Published values for the selectable DPT models at 220 V / 50 Hz. High and Low rows identify the available operating gear where applicable.
High / Low rows show the published operating gears. DPT-250P and DPT-315P are published as single-gear models.
| Modell | Operating gear | Leistung (W) | Luftstrom (m³/h) | Static pressure (Pa) | Speed (rpm) | Geräusch (dB) | Net weight (kg) | Duct size (mm) |
|---|---|---|---|---|---|---|---|---|
| DPT-100P | High | 40 | 204 | 132 | 2400 | 31 | 1.55 | φ100 |
| DPT-100P | Low | 30 | 160 | 106 | 1950 | 26 | 1.55 | φ100 |
| DPT-150P | High | 60 | 450 | 280 | 2590 | 33 | 2.5 | φ150 |
| DPT-150P | Low | 48 | 360 | 240 | 1950 | 29 | 2.5 | φ150 |
| DPT-200P | High | 145 | 840 | 350 | 2490 | 63 | 3.1 | φ200 |
| DPT-200P | Low | 125 | 690 | 270 | 1980 | 55 | 3.1 | φ200 |
| DPT-250P | Single | 230 | 1400 | 489 | 2450 | 66 | 7.5 | φ250 |
| DPT-315P | Single | 360 | 2200 | 690 | 2350 | 69 | 10.4 | φ315 |
Use the airflow-static pressure curve together with the installed duct route to verify the operating point before quotation.
Dimensions (mm)
DPT dimensions by model
| Modell | L | W | H | E |
|---|---|---|---|---|
| DPT-100P | 257 | 180 | 215 | φ99 |
| DPT-150P | 302 | 210 | 245 | φ148 |
| DPT-200P | 302 | 230 | 270 | φ198 |
| DPT-250P | 390 | 280 | 310 | φ248 |
| DPT-315P | 450 | 320 | 413 | φ313 |

What a mixed flow fan is, and when it is the right choice
A mixed flow impeller combines two airflow principles in one wheel. It moves air axially along the duct, as an axial fan does, while the shaped blades also accelerate the air outward as a centrifugal fan would. The result sits between the two types: more static pressure than a plain axial fan, in a shorter and more compact body than a centrifugal unit.
That combination is why the mixed flow duct fan format is common in ducted ventilation. Where an axial fan would lose performance against a longer duct run or a filter, and a centrifugal fan would need more room to install, an inline mixed flow fan can be fitted directly into the duct while still developing the pressure the run requires.
How to tell whether a mixed flow fan is the right fit
- Duct length and bends. Short, open runs suit an axial fan. Once the run is long or has several bends, the pressure demand rises and a mixed flow or centrifugal fan becomes the better fit.
- Available space. A mixed flow inline fan sits in the duct line, so it needs no separate plant space or bulky housing. A centrifugal fan may move more air at high pressure, but it needs the room to do it.
- Noise sensitivity. Because the impeller does more of the work internally, the sound profile differs from an axial fan. Where the duct passes occupied space, compare the published noise figure for the specific model rather than a family average.
- Airflow target. Read the published airflow and static pressure together. A model rated at a high free-air airflow can still underperform if the duct resistance is higher than its pressure figure allows.
Mixed flow inline fan, mixed flow duct fan or inline mixed-flow duct fan?
These names describe the same product family, and buyers use them interchangeably. A mixed flow inline fan, a mixed flow duct fan, an inline mixed-flow fan and an inline mixed-flow duct fan all refer to a fan whose impeller combines axial and centrifugal airflow and which mounts within the duct line. If a specification or a supplier uses one of these terms, confirm the duct diameter, the airflow and the static pressure — those three values decide whether the unit works in the installation, not the wording of the name.
If the format is still open, the comparison guide Inline Duct Fan vs Mixed-Flow Fan sets out where each type fits. Where sound is the deciding factor, review the silent mixed flow inline duct fan series instead.
Where this inline duct fan fits
View application fit and project inputs
Mixed Flow Inline Fan is suited for low-noise, high-pressure duct ventilation on supply or exhaust routes where the buyer needs compact inline installation and a defined duct path.
Für lange Kanalwege, mehrere Bögen, Filterwiderstand oder strenge Lärmvorgaben bestätigen Sie den statischen Druck, statt nur nach Nennluftstrom auszuwählen.
Zentrale Konstruktionsmerkmale
DPT model performance set against the published values on this page. Every point below is taken from this model’s own data.
Qualitätssicherung & Garantie
Ventilatorbestellungen werden vor dem Versand im Werk geprüft, denn veröffentlichter Luftstrom und Druck gelten nur, wenn das gelieferte Gerät seiner Tabellenzeile entspricht.
Applied to this model: Operating gear High, Power (W) 40. These checks are run against that specification before the unit ships.
OEM/ODM & Supply Options
Für Distributoren und Auftragnehmer in Lüftungsprojekten passt sich die Lieferseite Ihrem Markt an statt einer festen Ventilatorkonstruktion.
For this model (Operating gear High, Power (W) 40), the OEM route can start from that base specification rather than a blank sheet.
Dokumente & Compliance
Download the KC mixed flow inline fan datasheet used for the technical values on this page, and review the relevant compliance documents.
Bestätigen Sie das genaue Modell, die Anforderungen des Zielmarkts und die aktuelle Dokumentation vor Angebot oder Projektdokumentation.
Alle Zertifizierungen und Compliance-Dokumente nach Produktumfang ansehen
Häufig gestellte Fragen
Read the selection FAQ
Kann ich allein nach Kanaldurchmesser auswählen?
Nein. Der Kanaldurchmesser ist nur der Ausgangspunkt. Bestätigen Sie Luftstrom, statischen Druck, Kanallänge und Bögen.
Warum den statischen Druck bestätigen?
Lange Kanäle, Filter und Bögen verringern den tatsächlichen Luftstrom. Der statische Druck hilft, eine Unterdimensionierung zu vermeiden.
Welche Informationen werden für ein Angebot benötigt?
Senden Sie Kanaldurchmesser, Verlauf, Luftstromziel, Kanallänge, Bögen, Auslasstyp, Spannung/Frequenz, Stückzahl und Zielort.
ANGEBOTSROUTE
Request a review for your selected DPT model
Send the selected model, duct conditions and quantity for technical review.
Final quote review requires confirmation of the model, operating mode and installation requirements.