HT-DG158A-B Industrial Dehumidifier | 156 L/D Moisture Control
156 industrial dehumidifier for moisture-control projects
- CONTROLLO DELL'UMIDITÀ
- 156 industrial dehumidifier for moisture-control projects
- CONTROLLO ALIMENTAZIONE
- AC220V-50Hz; confirm exact circuit before ordering
- NOTA DI SELEZIONE
- Confermare il carico del locale, l'umidità target e il piano di drenaggio prima del preventivo
HT-DG158A-B Industrial Dehumidifier | 156 L/D Moisture Control
HT-DG158A-B is an industrial dehumidifier option for warehouses, production rooms, storage areas and equipment spaces where moisture control affects comfort, corrosion risk, product storage or process stability.
Flusso di selezione
Flusso di progetto
Idoneità all'applicazione
Dove questo modello è adatto e cosa verificare per primo
Technical Parameters
| Modello | Dehumidification | Voltage | Input power | Portata d'aria | Size |
|---|---|---|---|---|---|
| HT-DG158A-B | 156 | AC220V-50Hz | 1400 | 530 | 410x385x915 |
Conferma del progetto: Confermare il modello esatto, l'alimentazione elettrica, l'ambiente operativo, lo spazio di installazione e i documenti richiesti prima dell'approvazione finale dell'ordine.
Best-fit Applications
This model covers rooms where the moisture load sits between the mid-range and three-phase units. It suits a large workshop or store on single-phase power, with 530 m³/h of circulation to move dry air across the space.
The A and B variants are not identical, so the variant matters as much as the capacity. Confirm which one your project requires, along with the 1,400 W circuit load and the drain arrangement.
- Large rooms on 220 V: handles a bigger load without a three-phase supply.
- Storage and workshops: protects stock and tools across a large footprint.
- Variant-specific sites: where the A or B build suits the installation.
Selection guide
- Variant: confirm whether the A or B build suits the project.
- Moisture load: check litres per day against 156 L/D with margin.
- Air path: use the 530 m³/h circulation across the room.
- Supply: single-phase 220 V, circuit sized for 1,400 W.
- Drain route: plan continuous drainage for long running.
What NOT to Buy
| Situation | Risk | Better action |
|---|---|---|
| Variant not confirmed | The wrong build may not suit the installation. | Match the A or B variant to the site first. |
| Load above 156 L/D | The unit will fall short of target RH. | Move to a three-phase model. |
| No drain plan | Continuous running needs a reliable drain. | Arrange gravity or pump drainage. |
| Vague temperature data | Cold rooms cut performance. | Confirm the working range. |
Industrial Dehumidifier Buyer Checklist
Use the source-backed product information on this page as the starting point, then confirm site conditions before approving the final model.
- Which variant, A or B, suits the project
- Daily moisture load against 156 L/D
- Drain method and route
- 220 V circuit sized for 1,400 W
HT-DG158A-B is positioned for industrial workshop and warehouse dehumidification; confirm capacity, drainage and site humidity load before final selection.
Core Engineering Features
HT-DG158A-B Industrial Dehumidifier | 156 L/D Moisture Control set against the published values on this page. Every point below is taken from this model’s own data.
Quality Assurance & Warranty
Dehumidifier orders are verified at the factory before shipping, because a unit sized for a humidity target is only useful if it arrives working to that target.
Applied to this model: Capacity 156 L/D, Power AC220V-50Hz. These checks are run against that specification before the unit ships.
OEM/ODM & Supply Options
For distributors and contractors working on moisture-control projects, the supply side adapts to your market instead of one fixed cabinet build.
For this model (Capacity 156 L/D, Power AC220V-50Hz), the OEM route can start from that base specification rather than a blank sheet.
Documenti & conformità
This dehumidifier series is supported by Linggong Electric CE LVD/EMC and RoHS documentation for the listed HT, LG, HT-DG, LG-DG and LG-D dehumidifier model ranges.
- CE AttestationM.2025.206.C118876
- Technical FilesDTCF0509-LVD/EMC and DTCF0509-ROHS
- ApplicantZhejiang Linggong Electric Appliance Co., Ltd.
Scope boundary: use these documents for the dehumidifier model families listed in the certificates. The DTS1250 SGS performance report is not used here because its applicant/model scope does not match Linggongshare pages.
FAQ
How do I choose dehumidifier capacity?
Check the daily moisture load against 156 L/D, and confirm which variant, A or B, your project needs, because they are not identical. The 530 m³/h circulation then decides how well dry air reaches the room.
Can it run continuously?
Yes, on 220 V at 1,400 W, with a continuous drain in place. Confirm the variant and the circuit before installation, and make sure the load stays within 156 L/D. Service the filter and keep the 530 m³/h air path clear, and check the drain runs without restriction. Match any replacement parts to the correct A or B variant.
Download product catalog PDF
Download the English product catalog PDF for HT-DG158A-B Industrial Dehumidifier | 156 L/D Moisture Control. Use it for model comparison, technical review and inquiry preparation.
Use the exact model, voltage and installation conditions for project selection.
Confirm the published specifications, then add this product to your quote list.Product inquiry





