HT-15NE1 Industrial Dehumidifier | 10 kg/h Moisture Control
Deumidificatore industriale da 10kg/h per progetti di controllo dell'umidità
- CONTROLLO DELL'UMIDITÀ
- Deumidificatore industriale da 10kg/h per progetti di controllo dell'umidità
- CONTROLLO ALIMENTAZIONE
- AC380V/50Hz; confermare il circuito esatto prima di ordinare
- NOTA DI SELEZIONE
- Confermare il carico del locale, l'umidità target e il piano di drenaggio prima del preventivo
HT-15NE1 Constant Temperature Dehumidifier | Industrial Humidity Control
HT-15NE1 is an industrial dehumidifier option for warehouses, production rooms, storage areas and equipment spaces where moisture control affects comfort, corrosion risk, product storage or process stability.
Flusso di selezione
Flusso di progetto
Idoneità all'applicazione
Dove questo modello è adatto e cosa verificare per primo
Technical Parameters
| Modello | Dehumidification | Voltage | Input power | Portata d'aria | Size |
|---|---|---|---|---|---|
| HT-15NE1 | 10 kg/h | AC380V/50Hz | 3.7 kW | 4800 | 800x600x1850 |
Conferma del progetto: Confermare il modello esatto, l'alimentazione elettrica, l'ambiente operativo, lo spazio di installazione e i documenti richiesti prima dell'approvazione finale dell'ordine.
Best-fit Applications
This model suits larger rooms where humidity must come down but temperature must stay put. With 4,800 m³/h of circulation it reaches further than the standard constant-temperature unit, which helps in a bigger process room, lab or storage hall.
It runs on three-phase 380 V, removes 10 kg/h, and keeps the room temperature stable as it works. Where a temperature drop would damage product or disrupt a process, this is the correct type of unit rather than a standard cooling dehumidifier.
- Larger process rooms: controls humidity across a bigger space without shifting temperature.
- Labs and clean areas: holds conditions stable where both humidity and temperature matter.
- Storage halls: protects goods that react to damp and to temperature swings alike.
Selection guide
- Umidità e temperatura: confirm both targets before selecting this type of unit.
- Capacità in kg/h: verificare il tasso di rimozione rispetto al carico del locale.
- Air distribution: use the 4,800 m³/h circulation in a larger room.
- Supply: trifase 380 V, previsto per 3,7 kW.
- Drain route: scarico continuo per lunghi periodi di funzionamento.
What NOT to Buy
| Situation | Risk | Better action |
|---|---|---|
| Cooling needed | This unit holds temperature rather than lowering it. | Use a standard dehumidifier. |
| Small room | 4,800 m³/h is more airflow than a small room needs. | Consider the HT-15NE instead. |
| Sito monofase | It requires three-phase 380 V. | Confirm the supply first. |
| Undefined targets | Without both targets the selection is guesswork. | Set humidity and temperature first. |
Industrial Dehumidifier Buyer Checklist
Use the source-backed product information on this page as the starting point, then confirm site conditions before approving the final model.
- Humidity target and the temperature to be held
- Tasso di rimozione rispetto a 10 kg/h
- Circulation for 4,800 m³/h in a larger room
- Three-phase 380 V, 3.7 kW, plus continuous drain
HT-15NE1 is positioned for temperature-controlled industrial dehumidification; confirm capacity, drainage and site humidity load before final selection.
Core Engineering Features
HT-15NE1 Constant Temperature Dehumidifier | Industrial Humidity Contr set against the published values on this page. Every point below is taken from this model’s own data.
Quality Assurance & Warranty
Dehumidifier orders are verified at the factory before shipping, because a unit sized for a humidity target is only useful if it arrives working to that target.
Applied to this model: Capacity 10kg/h, Power AC380V/50Hz. These checks are run against that specification before the unit ships.
OEM/ODM & Supply Options
For distributors and contractors working on moisture-control projects, the supply side adapts to your market instead of one fixed cabinet build.
For this model (Capacity 10kg/h, Power AC380V/50Hz), the OEM route can start from that base specification rather than a blank sheet.
Documenti & conformità
This dehumidifier series is supported by Linggong Electric CE LVD/EMC and RoHS documentation for the listed HT, LG, HT-DG, LG-DG and LG-D dehumidifier model ranges.
- CE AttestationM.2025.206.C118876
- Technical FilesDTCF0509-LVD/EMC and DTCF0509-ROHS
- ApplicantZhejiang Linggong Electric Appliance Co., Ltd.
Scope boundary: use these documents for the dehumidifier model families listed in the certificates. The DTS1250 SGS performance report is not used here because its applicant/model scope does not match Linggongshare pages.
FAQ
How do I choose dehumidifier capacity?
Confirm both the humidity target and the temperature that must be held, then check the load against 10 kg/h. With 4,800 m³/h it suits a larger room than the HT-15NE.
Can it run continuously?
Yes, on three-phase 380 V. It holds room temperature while removing moisture, so it fits continuous duty in larger process and storage rooms where a temperature drop would spoil the work. Filter cleaning, a clear 4,800 m³/h air path and a free drain cover the routine work. Confirm service access for a tall cabinet, since a larger constant-temperature unit runs long hours.
Download product catalog PDF
Download the English product catalog PDF for HT-15NE1 Industrial Dehumidifier | 10 kg/h Moisture Control. Use it for model comparison, technical review and inquiry preparation.
Use the exact model, voltage and installation conditions for project selection.
Confirm the published specifications, then add this product to your quote list.Product inquiry





