Source-backed Silent In-Line Series parameters: partial model coverage
Source publiée : KCVENTS Silent In-Line Series technical table. Exact source coverage is limited to the ten models listed below. Target models DPT15-40, DPT20-150, DPT20-70, DPT25-210, DPT25-260 and DPT25-320 are not covered by this source and remain pending verification.
| Modèle | Voltage (V/Hz) | Speed | Puissance (W) | Débit d'air (m³/h) | Pression statique (Pa) | Bruit (dB) | Duct Diameter Φ (mm) |
|---|---|---|---|---|---|---|---|
| DP | 220-50 | / | 23 | 100 | 80 | 20 | 100 |
| DPT10-24B | 220-50 | H/B | 30/23 | 200/150 | 125/100 | 23 | 100 |
| DPT15-32B | 220-50 | H/B | 42/33 | 360/250 | 160/120 | 27 | 150 |
| DPT15-42B | 220-50 | H/B | 103/88 | 500/400 | 190/165 | 29 | 150 |
| DPT20-54B | 220-50 | H/B | 114/101 | 770/600 | 200/195 | 35 | 200 |
| DPT20-54C | 220-50 | H/B | 174/146 | 920/800 | 240/220 | 37 | 200 |
| DPT20-65B | 220-50 | H/B | 253/210 | 1200/1000 | 360/320 | 41 | 200 |
| DPT25-76B | 220-50 | H/B | 535/480 | 1700/1500 | 420/410 | 43 | 250 |
| DPT25-76C | 220-50 | H/B | 565/500 | 1900/1800 | 430/425 | 46 | 250 |
| DPT25-86B | 220-50 | H/B | 800/728 | 2600/2400 | 530/510 | 46 | 250 |
Inline Box Fan Selection Snapshot
Confirm whether a single-way inline box fan fits the duct route and service space before final model approval. Final quotation depends on duct size, installation space, airflow target, static pressure, duct length, bends, voltage, frequency and quantity.
HF Series coverage is 100% with high-confidence parameter rows in the PIM/source database. Do not copy values across unrelated duct fan pages.
Use the exact HF model row for selection
| Spec item | How to use it | Buyer check |
|---|---|---|
| Airflow | Use the exact HF variant source row | Match room volume and ventilation objective. |
| Static pressure | Check against duct length, bends and outlet resistance | Do not choose by airflow alone. |
| Noise | Use documented checks dBA value and installation context | Confirm if the fan is near occupied areas. |
| Voltage/frequency | Confirm before order | Match local project power supply. |
Where this inline duct fan fits
Single Way Inline Box Fan is suited for boxed inline duct ventilation with serviceable installation space where the buyer needs compact inline installation and a defined duct route.
For long duct runs, multiple bends, filter resistance or strict noise targets, confirm static pressure instead of selecting by nominal airflow only.
- Duct diameter and duct length
- Number of bends and outlet type
- Airflow target and noise limit
- Voltage/frequency and quantity
Core Engineering Features
Source-backed Silent In-Line Series parameters: partial model coverage set against the published values on this page. Every point below is taken from this model’s own data.
Quality Assurance & Warranty
Fan orders are checked at the factory before shipping, because published airflow and pressure only hold if the delivered unit matches its table row.
Appliqué à ce modèle : ventilateur en ligne à caisson unidirectionnel adapté au projet, application : ventilation de gaine en ligne sous caisson avec espace d’installation accessible pour l’entretien. Ces contrôles sont exécutés par rapport à cette spécification avant l’expédition de l’unité.
OEM/ODM & Supply Options
For distributors and contractors working on ventilation projects, the supply side adapts to your market instead of one fixed fan build.
Pour ce modèle (ventilateur en ligne à caisson unidirectionnel adapté au projet, application : ventilation de gaine en ligne sous caisson avec espace d’installation accessible pour l’entretien), la voie OEM peut partir de cette spécification de base plutôt que d’une feuille blanche.
Documents & conformité
Download the In-Line Series datasheet used for the technical values on this page, and review the relevant compliance documents.
Confirm the exact model, destination-market requirements and current documentation before quotation or project documentation.
View all certifications and compliance documents by product scope
Frequently asked questions
Can I choose by duct diameter only?
No. Duct diameter is only the starting point. Confirm airflow, static pressure, duct length and bends.
Why confirm static pressure?
Long ducts, filters and bends reduce actual airflow. Static pressure helps avoid under-selection.
What information is needed for quote?
Send duct diameter, route, airflow target, duct length, bends, outlet type, voltage/frequency, quantity and destination.
Product inquiry
Confirm the published specifications, then add this product to your quote list.