🎯 Trouvez le bon produit de ventilation
Demandez à notre IA CVC — obtenez des spécifications et une recommandation en quelques secondes

Single Room HRV VT501-WiFi

VT501 / VT501-WF / VT501-MS for single-room fresh-air ventilation with heat recovery and optional smart control

Airflow20–60 m³/h · 4 stages
Wall / Tube250–500 mm
Voltage12VDC or 100–240V
ControlWIFI / Remote
ADÉQUATION AU PROJET
Compact wall-install · operating modes Sleep / I / II / III

▶

Why VT501-WiFi for single-room fresh air

95% Recovery

Ceramic heat exchanger

Recovers up to 95% of thermal energy, so fresh air arrives without throwing away conditioned air.

Smart Control

Remote or WiFi operation

Choose the standard remote model or the WiFi model with Tuya app control, CO2 monitoring and automation.

Dual Filter

HEPA + activated carbon

Multi-stage filtration reduces pollen, dust, PM and outdoor odors before supply air enters the room.

Quiet Room

Under 30 dB operation

A brushless DC motor and sound-sealed design suit bedrooms, nurseries and home offices.

3 Modes

Fresh, exhaust and cycle

Fresh Air, Exhaust and 65-second Cycle modes give practical control over room ventilation.

DIY Fit

Single-hole wall install

No central ductwork required. It installs through an exterior wall with a telescopic duct and room-side panel.

Source-backed VT501-WiFi HRV parameters

Source publiée : KCVENTS VT501 technical table.

Parameter Sommeil I II III
Installation tube / wall thickness 250–500 mm
Voltage 12VDC or 100–240V 50–60Hz
Puissance totale du ventilateur (W) 2.5 3.0 4.5 8.5
Ventilator Current (A) 0.025 0.030 0.045 0.070
Débit d'air (m³/h) 20 48 54 60
Vitesse (tr/min) 630 1100 1600 2200
Noise Level (dB(A)) 12 20.0 24.0 30.0
Température de l’air transporté -20 °C (-4 °F) à +50 °C (122 °F)
Efficacité d’échange thermique up to 95%
Noyau de l’échangeur de chaleur Ceramic

How to select the right VT501 version

VT501 comes in three control versions for single-room fresh-air ventilation with heat recovery: VT501 (base), VT501-WF (WiFi) and VT501-MS.

Pick the airflow stage

Four stages (20 / 48 / 54 / 60 m³/h) suit bedrooms, offices and small rooms. Match the stage to room size and occupancy.

Check wall / tube depth

The installation tube fits 250–500 mm wall thickness. Measure the actual opening before ordering.

Choose the control

Base remote control or WiFi version with app control. Confirm which is required for the project.

Where this single-room HRV fits

VT501 / VT501-WF / VT501-MS is a room-by-room ventilation route for bedrooms, offices and other spaces where a central ventilation system is not the selected installation approach.

Fit boundary: For whole-building balanced ventilation, confirm whether a central ERV or multi-room design is required.

Frequently asked questions

Can this replace a central ERV?

It is mainly a room-by-room retrofit option. For whole-building balanced ventilation, confirm a central ERV or multi-room design.

What must be checked before order?

See the order checklist above: control version, wall thickness, airflow stage, power supply and quantity.

Are the listed values final for every version?

No. The values are source-backed from PDF p.6; confirm the exact version and order configuration for quote review.

Certification & quality assurance

100% pre-shipment inspection

Every batch undergoes functional and dimensional checks so that every unit arrives ready for installation: ceramic core fit, filter placement, remote and WiFi response, airflow mode switching, wall tube sizing and noise verification.

Hardware warranty support

In the rare event of a material defect or mechanical failure under standard operation, a straightforward replacement service protects your project timeline.

Before you order: confirm checklist

  • Control version: VT501 (remote) or VT501-WF (WiFi)
  • Wall thickness and installation tube length (250–500 mm)
  • Airflow stage (Sleep / I / II / III) and operating mode
  • Power supply and quantity

Core Engineering Features

Why VT501-WiFi for single-room fresh air set against the published values on this page. Every point below is taken from this model’s own data.

Pick the airflow stageFour stages (20 / 48 / 54 / 60 m³/h) suit bedrooms, offices and small rooms. Match the stage to room size and occupancy.
Check wall / tube depthThe installation tube fits 250–500 mm wall thickness. Measure the actual opening before ordering.
Choose the controlBase remote control or WiFi version with app control. Confirm which is required for the project.
Installation tube / wall thickness250–500 mm

Quality Assurance & Warranty

Fan orders are checked at the factory before shipping, because published airflow and pressure only hold if the delivered unit matches its table row.

Applied to this model: Pick the airflow stage Four stages (20 / 48 / 54 / 60 m³/h) suit bedrooms, offices and small rooms. Match the stage to room size and occupancy., Check wall / tube depth The installation tube fits 250–500 mm wall thickness. Measure the actual opening before ordering.. These checks are run against that specification before the unit ships.

Airflow and pressure checkChecks cover motor start-up, impeller balance, airflow and static pressure verification, noise review and model-to-table parameter matching.
Documented complianceCE, RoHS and related files cover the listed fan families; see the documents section below.
Warranty supportWarranty for fan orders is confirmed with the quotation for your destination market.
Service parts for fansImpellers, motor capacitors, mounting brackets and common service items.

OEM/ODM & Supply Options

For distributors and contractors working on ventilation projects, the supply side adapts to your market instead of one fixed fan build.

For this model (Pick the airflow stage Four stages (20 / 48 / 54 / 60 m³/h) suit bedrooms, offices and small rooms. Match the stage to room size and occupancy., Check wall / tube depth The installation tube fits 250–500 mm wall thickness. Measure the actual opening before ordering.), the OEM route can start from that base specification rather than a blank sheet.

OEM/ODMBadging, packaging and control options for fan orders, including branded cartons and manual inserts.
Airflow and pressure variantsModel selection, motor power and voltage options are reviewed against your duct calculation.
Voltage & plug optionsVoltage and plug configuration for this product line can be reviewed during quotation.
Documentation & bulk supplyCatalogues, technical sheets, available certificates, volume pricing and distributor programs for this product line.
Order quantity & lead timeMinimum order quantity, sampling and production lead time are confirmed per model and order volume — see the B2B supply page for how sourcing enquiries are handled.

Product inquiry

Have your control version, wall thickness, airflow stage and quantity ready, then add this product to your quote list.

Download the VT501 catalog







control-mode

,