🎯 Trouvez le bon produit de ventilation
Demandez à notre IA CVC — obtenez des spécifications et une recommandation en quelques secondes

Ceiling Exhaust Fan

Ceiling Exhaust Fan for general room ventilation in residential and light commercial ceiling-mounted applications

ADÉQUATION AU PROJET
Ceiling Exhaust Fan for general room ventilation in residential and light commercial ceiling-mounted applications
PLAGE DE PERFORMANCES
Single model · standard ceiling exhaust · suitable for general room ventilation
Project quotation availableAdd this product to your quote, then include your preferred model and project requirements in the inquiry.

Ce produit est actuellement en rupture et indisponible.

Exhaust fan selection

Ceiling Exhaust Fan Selection Snapshot

Use this model when the buyer needs a small-room ceiling exhaust point and wants to avoid wrong opening size, weak airflow or unnecessary installation rework.

Project fitsmall-room ceiling exhaust
Applicationbathroom, washroom and small-room exhaust
Decision valuehelps screen fit quickly before deeper quote comparison
Selection rule

Use this model to reduce wrong-size and wrong-route risk for product selection. Confirm opening size, duct route, airflow/noise target and power supply before final order.

Product parameters

Ceiling Exhaust Fan Specifications

Reference dimensions and performance data for the BPT10-23 / BPT-10-23 ceiling exhaust fan model.

BPT10-23 ceiling exhaust fan size drawing showing A B C ΦD D and E dimensions
Use the size drawing together with the vertical dimension card to check panel size, duct diameter and installation depth for quote review.

BPT10-23 dimensions

Modèle
BPT10-23
A
300 mm
B
300 mm
C
100 mm
ΦD
98 mm
D
363 mm
E
237 mm

For buyers, this means a 300 × 300 mm visible panel, a 300 × 300 mm opening reference and about 100 mm class duct connection planning.

Size note: A/B are panel width and height; ΦD is duct diameter; C/D/E support side-view installation depth checks.

Performance
Modèle Voltage(V) Power(W) Airflow(m³/h) Static Pressure(Pa) Noise(dB) G.W (kg) Hole Size (mm) Panel Size (mm) Dimension du conduit (mm) Carton/Pièce
BPT10-20-12SL 220 30 120 65 42 1.4 200*200 245*245 100 8
BPT10-23-155L 220 40 150 65 42 1.4 230*230 270*270 100 8
BPT10-25-175L 220 40 170 95 41 1.7 250*250 304*304 100 8
BPT10-28-215L 220 34 210 165 43 1.8 280*280 320*320 100 8
BPT10-30-30SL 220 45 300 200 45 2.1 300*300 335*335 100 8
BPT10-34-40SL 220 45 400 205 46 2.2 340*340 400*400 100 4
BPT15-34-50SL 220 50 500 210 47 2.2 340*340 400*400 150 4
Ceiling Exhaust Fan model dimensions
Modèle A B C D φE
BPT10-20-12SL 200 209 240 30 100
BPT10-23-155L 230 238 270 30 100
BPT10-25-175L 250 275 310 30 100
BPT10-28-215L 275 279 320 30 95
BPT10-30-30SL 300 301 340 30 100
BPT10-34-40SL 340 343 400 30 100
BPT15-34-50SL 340 340 400 30 150
Buyer fit

Who this BPT-10-23 ceiling exhaust fan fits

Installer / contractor

Use this model when the project needs a 300 × 300 mm ceiling panel, 300 × 300 mm opening and 100 mm duct connection. The compact 2.1 kg unit is suitable for small-room ceiling exhaust points where installation space is limited.

Distributor / reseller

Position BPT-10-23 as a compact ceiling-mounted exhaust fan for bathrooms, washrooms and small rooms. Key quote facts are 200V~50Hz, 30 W, 180 m³/h airflow, 98 Pa static pressure and 42 dB(A) noise.

Property / project buyer

Choose this page when the requirement is a simple overhead exhaust point rather than a large duct fan. Confirm whether 180 m³/h airflow and 42 dB(A) noise meet the room target for final selection.

Not the right fit

Do not use this model as a replacement for high-airflow duct systems or long duct runs without checking resistance. If the project needs higher airflow, larger duct size or lower noise, compare other exhaust fan models first.

Demand fit

What need does this model help solve

For quiet small-room exhaust

Use this model when the buyer needs a simple ceiling exhaust point for bathrooms, washrooms or small rooms without moving to a larger duct fan solution.

What worry it reduces

The 300 × 300 panel, 100 mm duct and 180 m³/h airflow help screen opening-size mismatch and underpowered small-room exhaust for final selection.

When to compare other models

If the project needs longer duct runs, higher airflow, lower noise or larger duct size, compare other exhaust fan models before approving this one.

Next safe step

Send opening size, duct route, voltage and quantity when the buyer wants faster quote confirmation with lower rework risk.

Selection guide

Selection guide

1. Define room need

Bathroom, utility room, commercial restroom, workshop or sidewall exhaust.

2. Confirm air route

Ceiling duct, direct wall route, shutter opening or panel installation.

3. Match performance

Confirm airflow, noise target, duct length and bends.

4. Request confirmation

Send model, quantity, voltage and destination for selection support.

Fit check

Compare the options

Use the official Exhaust Fans Collection Hub when comparing ceiling, wall, EC bathroom and shutter exhaust fan options.

Core Engineering Features

Ceiling Exhaust Fan Selection Snapshot set against the published values on this page. Every point below is taken from this model’s own data.

Project fitsmall-room ceiling exhaust
Applicationbathroom, washroom and small-room exhaust
Decision valuehelps screen fit quickly before deeper quote comparison
Voltage(V)220
Power(W)30
Airflow(m³/h)120

Quality Assurance & Warranty

Fan orders are checked at the factory before shipping, because published airflow and pressure only hold if the delivered unit matches its table row.

Applied to this model: Project fit small-room ceiling exhaust, Application bathroom, washroom and small-room exhaust. These checks are run against that specification before the unit ships.

Airflow and pressure checkChecks cover motor start-up, impeller balance, airflow and static pressure verification, noise review and model-to-table parameter matching.
Documented complianceCE, RoHS and related files cover the listed fan families; see the documents section below.
Warranty supportWarranty for fan orders is confirmed with the quotation for your destination market.
Service parts for fansImpellers, motor capacitors, mounting brackets and common service items.

OEM/ODM & Supply Options

For distributors and contractors working on ventilation projects, the supply side adapts to your market instead of one fixed fan build.

For this model (Project fit small-room ceiling exhaust, Application bathroom, washroom and small-room exhaust), the OEM route can start from that base specification rather than a blank sheet.

OEM/ODMBadging, packaging and control options for fan orders, including branded cartons and manual inserts.
Airflow and pressure variantsModel selection, motor power and voltage options are reviewed against your duct calculation.
Voltage & plug optionsVoltage and plug configuration for this product line can be reviewed during quotation.
Documentation & bulk supplyCatalogues, technical sheets, available certificates, volume pricing and distributor programs for this product line.
Order quantity & lead timeMinimum order quantity, sampling and production lead time are confirmed per model and order volume — see the B2B supply page for how sourcing enquiries are handled.

Documents & conformité

Download the metal exhaust fan datasheet used for the technical values on this page, and review the relevant compliance documents.

Confirm the exact model, destination-market requirements and current documentation before quotation or project documentation.

Frequently asked questions

How do I choose this model?

Start from the installation route and room use, then confirm the exact model datasheet or database row.

Can I use generic fan values?

No. Use only confirmed source values for airflow, noise, power and dimensions.

What should I send for quotation?

Send room type, opening size, duct path, airflow target, voltage, quantity and destination.

Product inquiry

Confirm the published specifications, then add this product to your quote list.

modèle

, , , , , ,