High Pressure Air Cabinet Fan
DT high-pressure cabinet fan for long-duct commercial kitchen and high-resistance exhaust systems
- IDONEITÀ AL PROGETTO
- DT high-pressure cabinet fan for long-duct commercial kitchen and high-resistance exhaust systems
- RANGE DI PRESTAZIONI
- 4 models · 6,500–12,000 m³/h · 380V · static pressure 520–710 Pa · industrial-grade airflow
Panoramica di selezione del ventilatore a cassetta
High Pressure Air Cabinet Fan range for high-static-pressure cabinet ventilation with industrial-grade ducted airflow. Check the model table for airflow, static pressure, and dimensions before specifying.
Sono mostrate solo le righe ad alta affidabilità. I modelli non correlati per estrazione fumi sono esclusi da questo lotto Cabinet/KTJ/DT.
Verifiche dei modelli ad alta affidabilità
| Modello | Voltage | Potenza W | Portata d'aria m³/h | Pressione statica Pa | Rumorosità dB(A) | Dimensioni uscita / filtro | Fonte |
|---|---|---|---|---|---|---|---|
| DT28-6000 | 380 | 1500 | 6500-4800 | 520-710 | 64 | 405×285 | 13 |
| DT30-10000 | 380 | 3000 | 10500-8500 | 720-800 | 70 | 430×300 | 13 |
| DT30-8000 | 380 | 2200 | 8500-6500 | 640-740 | 67 | 430×300 | 13 |
| DT32-12000 | 380 | 4000 | 12500-9000 | 740-850 | 73 | 405×330 | 13 |
Where this cabinet fan fits
Cabinet fans are selected when a project needs enclosed airflow, easier service access and a cleaner installation than an open fan. For kitchen or high-resistance routes, static pressure and oil/filter access matter as much as airflow.
Use the model table as a starting point, then confirm duct resistance, opening size and maintenance clearance for final selection.
- Airflow and static pressure at working point
- Voltage/frequency and motor protection requirement
- Inlet/outlet opening and filter size
- Inspection door, oil/water drain and cleaning access
Cabinet fan selection guide
General ventilation, filtered cabinet airflow, kitchen exhaust or long duct/high-pressure route.
Do not choose by airflow alone; static pressure and duct losses decide the usable model.
Confirm opening size, cabinet dimensions, mounting space and maintenance clearance.
Send duct route, airflow target, voltage and site photos for quote review.
KTJKTJ-GDT positioning
KTJ is suited to general cabinet ventilation, KTJ-G is better for filter/oil-management cabinet use, and DT high-pressure cabinet fans are better for longer or higher-resistance duct routes. HTFC smoke-exhaust products are a separate family and are not merged into this table.
Core Engineering Features
Cabinet Fan Selection Snapshot set against the published values on this page. Every point below is taken from this model’s own data.
Quality Assurance & Warranty
Fan orders are checked at the factory before shipping, because published airflow and pressure only hold if the delivered unit matches its table row.
Applied to this model: Project fit DT high-pressure cabinet fan for long-duct or high-resistance ventilation, Sample models DT28-6000 / DT30-10000 / DT30-8000 / DT32-12000. These checks are run against that specification before the unit ships.
OEM/ODM & Supply Options
For distributors and contractors working on ventilation projects, the supply side adapts to your market instead of one fixed fan build.
For this model (Project fit DT high-pressure cabinet fan for long-duct or high-resistance ventilation, Sample models DT28-6000 / DT30-10000 / DT30-8000 / DT32-12000), the OEM route can start from that base specification rather than a blank sheet.
Documenti & conformità
Download the high pressure air cabinet fan datasheet used for the technical values on this page, and review the relevant compliance documents.
Confirm the exact model, destination-market requirements and current documentation before quotation or project documentation.
View all certifications and compliance documents by product scope
Frequently asked questions
Posso selezionare solo in base alla portata d'aria?
No. La selezione del ventilatore da armadio deve includere pressione statica, percorso dei condotti, gomiti, dimensioni di ingresso/uscita e accesso per la manutenzione.
Sono elencati tutti i modelli?
No. La tabella mostra righe campione ad alta attendibilità dalla fonte PDF/PIM abbinata. Richiedi la scheda tecnica del modello esatto prima dell'ordine definitivo.
HTFC è incluso in questa pagina?
No. I ventilatori centrifughi da armadio per estrazione fumi HTFC richiedono una gestione separata della fonte e non devono essere mescolati con le tabelle dei ventilatori da armadio KTJ/DT.
Product inquiry
Confirm the published specifications, then add this product to your quote list.
| modello |
|---|