🎯 Trova il prodotto di ventilazione giusto
Chiedi alla nostra IA per HVAC — ottieni specifiche e consigli in pochi secondi

Cross-Flow Air Curtain B series

Cross-Flow Air Curtain B Series for retail and service entrances needing compact cross-flow air separation with a slim profile

IDONEITÀ AL PROGETTO
Cross-Flow Air Curtain B Series for retail and service entrances needing compact cross-flow air separation with a slim profile
RANGE DI PRESTAZIONI
Single model · cross-flow design · slim profile · standard commercial entrances
Source note

Panoramica di selezione

La barriera d'aria a flusso trasversale serie B è posizionata per aperture commerciali più larghe che richiedono una separazione d'aria a flusso trasversale più forte della serie Q. La tabella sotto utilizza righe supportate dal PDF CHIC 2026 e mantiene le diciture di affidabilità dove il modello sorgente corrisponde a una variante Linggong LK.

Source: CHIC GROUP HVAC 2026 PDF p.48 · medium source: source rows are FM models mapped to Linggong LK-FM variants; confirm exact order model
Varianti di esempioLK-FM4009 / LK-FM4012 / LK-FM4015 / LK-FM4018
Applicationwider commercial openings needing stronger cross-flow air separation than Q series
Fattori di selezioneConfirm opening width, mounting height, voltage, air speed requirement, noise target and exact LK-FM variant
Verifica di selezione

Air curtains must be selected by door width, mounting height, air speed and voltage. Medium rows require exact Linggong variant confirmation before final quotation.

Documented checks

Verifiche modello supportate da fonte

Cross-Flow Air Curtain B series technical and selection table
Linggong variant Modello sorgente PDF Voltage Alimentazione Portata d'aria m³/h Velocità aria m/s Rumore dB Dimensioni mm Confidence Next step
LK-FM4009 FM-4009 220-50 160 1630 11-13 53 900x175x210 medium Ask about this model
LK-FM4012 FM-4012 220-50 220 2500 11-13 54 1200x175x210 medium Ask about this model
LK-FM4015 FM-4015 220-50 260 3580 11-13 55 1500x175x210 medium Ask about this model
LK-FM4018 FM-4018 220-50 320 3900 11-13 56 1800x175x210 medium Ask about this model
LK-FM4020 FM-4020 220-50 350 4280 11-13 56 2000x175x210 medium Ask about this model
Idoneità all'applicazione

Dove è adatta questa barriera d'aria

Utilizzare questa serie quando l'apertura necessita di una barriera d'aria per ridurre polvere, insetti, scambio aria calda/fredda o perdita di aria condizionata.

Scegliere il modello in base a larghezza apertura e altezza di installazione, poi confermare velocità aria, livello di rumore, tensione e spazio di montaggio.

Send these details

  • Door width and mounting height
  • Indoor/outdoor temperature difference
  • Voltage and installation space
  • Noise target and required air speed
Confronta

Confronta famiglie di barriere d'aria

I modelli Q/B a flusso trasversale si adattano ad aperture generali, i modelli X5 e centrifughi industriali si adattano a esigenze di velocità aria più elevate, i modelli riscaldanti aggiungono aumento di temperatura, i modelli incassati a soffitto nascondono il corpo, e i modelli per celle frigorifere aiutano a ridurre la perdita di aria fredda.

Core Engineering Features

Source-backed model checks set against the published values on this page. Every point below is taken from this model’s own data.

Varianti di esempioLK-FM4009 / LK-FM4012 / LK-FM4015 / LK-FM4018
Applicationwider commercial openings needing stronger cross-flow air separation than Q series
Fattori di selezioneConfirm opening width, mounting height, voltage, air speed requirement, noise target and exact LK-FM variant
Voltage220-50
Alimentazione160
Portata d'aria m³/h1630

Quality Assurance & Warranty

Air curtain orders are checked at the factory before shipping, because barrier performance depends on discharge speed matching the door the unit serves.

Applied to this model: Sample variants LK-FM4009 / LK-FM4012 / LK-FM4015 / LK-FM4018, Application wider commercial openings needing stronger cross-flow air separation than Q series. These checks are run against that specification before the unit ships.

Discharge and length checkChecks cover motor start-up, discharge air speed, airflow, unit length and panel fit, plus model-to-table parameter matching.
Documented complianceCE and related files cover the listed air curtain families; see the documents section below.
Warranty supportWarranty for air curtain orders is confirmed with the quotation for your destination market.
Service parts for air curtainsMotors, PTC heating modules, control boards and common service items.

OEM/ODM & Supply Options

For distributors and contractors working on entrance projects, the supply side adapts to your market instead of one fixed air curtain build.

For this model (Sample variants LK-FM4009 / LK-FM4012 / LK-FM4015 / LK-FM4018, Application wider commercial openings needing stronger cross-flow air separation than Q series), the OEM route can start from that base specification rather than a blank sheet.

OEM/ODMBadging, packaging and control options for air curtain orders, including branded cartons and manual inserts.
Length and speed variantsUnit length, discharge speed and ambient or heated configuration are reviewed for your doorway.
Voltage & plug optionsVoltage and plug configuration for this product line can be reviewed during quotation.
Documentation & bulk supplyCatalogues, technical sheets, available certificates, volume pricing and distributor programs for this product line.
Order quantity & lead timeMinimum order quantity, sampling and production lead time are confirmed per model and order volume — see the B2B supply page for how sourcing enquiries are handled.

Documenti & conformità

Download the cross-flow air curtain B series datasheet (PDF) used for the technical values on this page.

Confirm the exact model and current documentation before quotation or project documentation.

Frequently asked questions

Can I choose by door width only?

No. Door width is only the first step; mounting height, air speed, voltage, heating need and noise target also matter.

Why do some rows say medium confidence?

The numeric source row is clear, but the PDF model may map to a Linggong LK-prefixed or combined variant. Confirm exact order model before final quotation.

What should I send for quote?

Send opening width, mounting height, voltage, indoor/outdoor conditions, preferred series and destination.

Product inquiry

Confirm the published specifications, then add this product to your quote list.

modello

, , , , ,