Single Way Fresh Air Inline Fan
Single Way Fresh Air Inline Fan for single-route fresh-air supply or exhaust duct ventilation in residential or light commercial applications
- PROJEKTEIGNUNG
- Single Way Fresh Air Inline Fan for single-route fresh-air supply or exhaust duct ventilation in residential or light commercial applications
- LEISTUNGSBEREICH
- 3 models · 220–380V · DPT series · compact inline design for single-route duct systems
Fresh Air Inline Fan Selection Snapshot
Confirm whether a single-way fresh-air inline fan fits the duct route before final model approval. Final quotation depends on duct diameter, route direction, airflow target, duct length, bends, outlet type, voltage, frequency and quantity.
Use the exact source row for this fan family; do not copy values across unrelated duct fan pages.
Use the exact HF model row for selection
| Spec item | How to use it | Buyer check |
|---|---|---|
| Luftvolumenstrom | Use the exact HF variant source row | Raumvolumen und Lüftungsziel abstimmen. |
| Static pressure | Prüfen gegen Kanallänge, Bögen und Auslasswiderstand | Nicht allein nach Luftstrom auswählen. |
| Noise | Use confirmed dBA value and installation context | Bestätigen Sie, ob der Ventilator nahe genutzter Bereiche liegt. |
| Voltage/frequency | Confirm before order | Zur lokalen Projektstromversorgung passen. |
DPT J-series performance and dimensions reference
Rows match the selectable models on this page and are transcribed from the first-party Beiaole DPT J-series technical table. Confirm the final model and current datasheet before quotation.
| Modell | Voltage(V) | Frequency(Hz) | Stufe | Power(W) | Airflow(m³/h) | Static Pressure(Pa) | Noise(dB) | Duct Size(mm) | Application Area(m²) | N.M(kg) |
|---|---|---|---|---|---|---|---|---|---|---|
| DPT10-35J | 220 | 50 | High | 53 | 160 | 192 | 31 | φ100 | 8-15 | 9 |
| DPT10-35J | 220 | 50 | Low | 44 | 120 | 170 | 25 | φ100 | 8-15 | 9 |
| DPT15-45J | 220 | 50 | High | 88 | 350 | 270 | 42 | φ150 | 25-30 | 11 |
| DPT15-45J | 220 | 50 | Low | 78 | 290 | 250 | 38 | φ150 | 25-30 | 11 |
| DPT20-55J | 220 | 50 | High | 143 | 650 | 365 | 45 | φ200 | 30-40 | 13 |
| DPT20-55J | 220 | 50 | Low | 122 | 500 | 300 | 32 | φ200 | 30-40 | 13 |
| Modell | L | L1 | L2 | W | W1 | H | H1 | D |
|---|---|---|---|---|---|---|---|---|
| DPT10-35J | 701 | 523 | 420 | 400 | 447 | 121 | 30 | φ100 |
| DPT15-45J | 673 | 523 | 420 | 400 | 447 | 196 | 30 | φ150 |
| DPT20-55J | 700 | 523 | 420 | 400 | 447 | 246 | 30 | φ200 |
Where this inline duct fan fits
Single Way Fresh Air Inline Fan is suited for single-route fresh-air supply or exhaust duct ventilation where the buyer needs compact inline installation and a defined duct route.
Für lange Kanalwege, mehrere Bögen, Filterwiderstand oder strenge Lärmvorgaben bestätigen Sie den statischen Druck, statt nur nach Nennluftstrom auszuwählen.
- Kanaldurchmesser und Kanallänge
- Number of bends and outlet type
- Luftstromziel und Lärmgrenze
- Spannung/Frequenz und Stückzahl
Duct fan selection guide
Fresh air supply, exhaust, grow-room circulation or split duct route.
Duct length, bends, filter, grille and outlet resistance affect real airflow.
Use confirmed HF variant values for airflow, pressure, power and noise.
Share site details before final model confirmation.
Compare inline duct fan options
For series-level comparison, use the official Fresh Air System Series Hub. Compare by duct route, static pressure, noise target and installation access.
Häufig gestellte Fragen
Kann ich allein nach Kanaldurchmesser auswählen?
Nein. Der Kanaldurchmesser ist nur der Ausgangspunkt. Bestätigen Sie Luftstrom, statischen Druck, Kanallänge und Bögen.
Warum den statischen Druck bestätigen?
Lange Kanäle, Filter und Bögen verringern den tatsächlichen Luftstrom. Der statische Druck hilft, eine Unterdimensionierung zu vermeiden.
Welche Informationen werden für ein Angebot benötigt?
Senden Sie Kanaldurchmesser, Verlauf, Luftstromziel, Kanallänge, Bögen, Auslasstyp, Spannung/Frequenz, Stückzahl und Zielort.
Download inline fan spec table (PDF)

Performance data
Download inline fan data sheet (part 2) (PDF)

Zentrale Konstruktionsmerkmale
Fresh Air Inline Fan Selection Snapshot set against the published values on this page. Every point below is taken from this model’s own data.
Qualitätssicherung & Garantie
Ventilatorbestellungen werden vor dem Versand im Werk geprüft, denn veröffentlichter Luftstrom und Druck gelten nur, wenn das gelieferte Gerät seiner Tabellenzeile entspricht.
Applied to this model: Project fit single-way fresh-air inline fan, Application single-route fresh-air supply or exhaust duct ventilation. These checks are run against that specification before the unit ships.
OEM/ODM & Supply Options
Für Distributoren und Auftragnehmer in Lüftungsprojekten passt sich die Lieferseite Ihrem Markt an statt einer festen Ventilatorkonstruktion.
For this model (Project fit single-way fresh-air inline fan, Application single-route fresh-air supply or exhaust duct ventilation), the OEM route can start from that base specification rather than a blank sheet.
Product inquiry
Bestätigen Sie die veröffentlichten Spezifikationen und fügen Sie dieses Produkt dann Ihrer Angebotsliste hinzu.





