EC-Motor-Jalousie-Abluftventilator
EC Motor Shutter Exhaust Fan for wall-mount sidewall exhaust in utility rooms, workshops, and equipment areas
- PROJEKTEIGNUNG
- EC Motor Shutter Exhaust Fan for wall-mount sidewall exhaust in utility rooms, workshops, and equipment areas
- LEISTUNGSBEREICH
- Single model · EC motor drive · shutter-type wall exhaust · energy-efficient sidewall ventilation
How the shutter works, and why it matters
A shutter exhaust fan is specified for two jobs at once: moving air, and closing the opening when the fan stops. Buyers searching for exhaust fans with shutters are usually solving the second problem — keeping rain, dust and backdraught out of the wall opening — so the shutter is part of the duty, not an accessory.
This EC motor shutter exhaust fan carries its own automatic shutter. When the fan runs, the blades swing open on the airflow; when it stops, they fall closed and the opening is sealed. That is the behaviour to look for in a shutter-mounted exhaust fan, and it is why the mounting hole size matters as much as the airflow figure.
- Fan diameter — 16 inches (40.6 cm), the size that sets the wall opening.
- Mounting hole — approximately 43 × 43 cm, so the rough opening can be prepared before the unit arrives.
- Overall size — 48.5 × 48.5 × 19.6 cm, which includes the shutter housing and the frame that sits on the wall face.
- Airflow and pressure — 2,560 CFM at approximately 96 Pa static pressure, published so the unit can be checked against duct or wall resistance.
- Control — EC motor with PWM 10-speed modulation and memory function, so the fan can run below maximum where the extra airflow is not needed.
- Protection — IP-44 rated for dust and water resistance, which is what allows the shutter side to face the weather.
Two practical notes when comparing an exhaust fan with shutter against a plain wall fan. First, confirm shutter clearance — the blades need room to swing, and a frame that is too tight will hold them part-open and leak. Second, check static pressure if a duct or grille sits behind the fan: a shutter fan rated at a fixed CFM delivers less air through a restricted path, and the published 96 Pa figure is the reference for that check.
For other wall and ceiling formats, compare the exhaust fan selection hub and the bathroom exhaust fan sizing guide.
EC Motor Shutter Exhaust Fan Selection Snapshot
Confirm whether an EC motor shutter exhaust fan fits the wall opening, shutter clearance and sidewall route before final model approval. Final quotation depends on wall opening size, shutter type, power supply, voltage, frequency and quantity.
Do not approve the model from the product name alone. Confirm mounting route, duct path, opening size, airflow/noise target and power supply.
EC Motor Shutter Exhaust Fan specifications
| Specification | Details |
|---|---|
| Fan Size | 16 inches (40.6 cm) |
| Overall Dimensions | 48.5 × 48.5 × 19.6 cm (19.09″ × 19.09″ × 7.72″) |
| Mounting Hole Size | Approx. 43 × 43 cm (16.92″ × 16.92″) |
| Airflow Capacity | 2,560 CFM (high-efficiency ventilation) |
| Static Pressure | 25.9 mm-H₂O (approx. 96 Pa) |
| Noise Level | 67–70 dBA |
| Motor Type | EC (Electronically Commutated), energy-efficient |
| Drive & Control | PWM intelligent modulation, 10-speed, with memory function |
| Power / Current | 100 W / 1.5 A (100–240 V AC, 50/60 Hz) |
| Bearings & Lifespan | Dual ball bearings, L10 67,000 hours |
| Ingress Protection | IP-44 rated, dust and water-resistant |
Where this exhaust fan fits
utility rooms, workshops and sidewall ventilation.
Confirm wall opening, shutter clearance and power supply for quote review.
Do not select only by product photo or generic category name.
Selection guide
Bad, Hauswirtschaftsraum, gewerblicher Sanitärraum, Werkstatt oder Seitenwand-Abluft.
Deckenkanal, direkter Wandweg, Jalousieöffnung oder Paneelmontage.
Bestätigen Sie Luftstrom, Lärmziel, Kanallänge und Bögen.
Senden Sie Modell, Stückzahl, Spannung und Zielort für Auswahlunterstützung.
Compare the options
Use the official Abluftventilatoren-Sammlung beim Vergleich von Decken-, Wand-, EC-Bad- und Jalousie-Abluftventilatoren.
Zentrale Konstruktionsmerkmale
EC Motor Shutter Exhaust Fan Selection Snapshot set against the published values on this page. Every point below is taken from this model’s own data.
Qualitätssicherung & Garantie
Ventilatorbestellungen werden vor dem Versand im Werk geprüft, denn veröffentlichter Luftstrom und Druck gelten nur, wenn das gelieferte Gerät seiner Tabellenzeile entspricht.
Applied to this model: Project fit shutter wall exhaust, Application utility rooms, workshops and sidewall ventilation. These checks are run against that specification before the unit ships.
OEM/ODM & Supply Options
Für Distributoren und Auftragnehmer in Lüftungsprojekten passt sich die Lieferseite Ihrem Markt an statt einer festen Ventilatorkonstruktion.
For this model (Project fit shutter wall exhaust, Application utility rooms, workshops and sidewall ventilation), the OEM route can start from that base specification rather than a blank sheet.
Dokumente & Compliance
Download the EC wall-mounted exhaust fan datasheet used for the technical values on this page, and review the relevant compliance documents.
Bestätigen Sie das genaue Modell, die Anforderungen des Zielmarkts und die aktuelle Dokumentation vor Angebot oder Projektdokumentation.
Alle Zertifizierungen und Compliance-Dokumente nach Produktumfang ansehen
Häufig gestellte Fragen
Wie wähle ich dieses Modell?
Beginnen Sie mit Installationsweg und Raumnutzung und bestätigen Sie dann das Datenblatt oder den Datenbankeintrag des genauen Modells.
Kann ich allgemeine Ventilatorwerte verwenden?
Nein. Verwenden Sie für Luftstrom, Lärm, Leistung und Abmessungen nur bestätigte Quellwerte.
Was sollte ich für ein Angebot senden?
Senden Sie Raumtyp, Öffnungsgröße, Kanalweg, Luftstromziel, Spannung, Stückzahl und Zielort.
Does this shutter exhaust fan close when it stops?
Yes. The blades swing open on the airflow while the fan runs and fall closed when it stops, sealing the wall opening against rain, dust and backdraught. This is the behaviour to check for when comparing exhaust fans with shutters.
Product inquiry
Bestätigen Sie die veröffentlichten Spezifikationen und fügen Sie dieses Produkt dann Ihrer Angebotsliste hinzu.